Back Cover Performance Data Sheet - GE GFSF6KEXCBB Owner's Manual And Installation Instructions

Bottom freezers refrigerators 26 models
Table of Contents

Advertisement

Available languages

Available languages

Performance
Data Sheet
SmartWater Filtration System
MWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter
USEPA
Influent
MCL
Challenge Concentration
Chlorine
-
2.0 mg/L ± 10%
T&O
-
-
Particulate**
-
_> 10,000 particles/mL
Influent
Average
1.96 mg/L
6,400,000 #/mL
Effluent
Average
Maximum
0.06 mg/L
0.11mg/L
58,833 # /mL
150,000 # /mL
% Reduction
Average
Minimum
96.77%
94.74%
99,14%
97,97%
Standard No. 53: Health Effects
Parameter
Effluent
Turbidity
Casts
Asbestos
Lead at pH 65
Lead at pH 85
Mercury at pH6.5
Mercury at pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dicNorobenzene
Atrazine
USEPA
MCL
0,5NTU
_> 99,95% Reduction
_> 99% Reduction
0.015mg/L
0.015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.040mg/L
0.075mg/L
0.003mg/L
Influent
Challenge Concentration
11+ 1NTU***
Minimum50,000L
107 to 108 fibers/L; > lOpm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
10.5NTU
118,750 #/L
57MF/L
0.1567mg/L
0.1433mg/L
0.0059mg/L
0.0057mg/L
0.0367mg/L
0.0020mg/L
0.2033mg/L
0.0160mg/L
0.0145mg/L
0.0830mg/L
0.2283mg/L
0.0087mg/L
Average
0.14NTU
< I#/L
0.996MF/L
< 0.001mg/L
< 0.001mg/L
0.000350mg/L
0.000325mg/L
0.00023 mg/L
<0.00002 mg/L
0.00337 mg/L
0.00100 mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
< 0.0005mg/L
Maximum
0.28NTU
4#/L
<1 MF/L
< 0.001mg/L
< 0.001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
< 0.00002 mg/L
0.011000 mg/L
0.001000 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
% Reduction
Average
Minimum
98.54%
97.20%
> 99.99%
> 99.99%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
96.51%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93,33%
Tested using a flow rate of 0.50 gpm; pressure
of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° +_5°F (20 ° +_3°C)
** Measurement
in Partictes/mt.
Particles used were 0.5-1 microns
*** NTU=Nephetometric
Turbidity
units
Min.Required
Reduction
>50%
_> 85%
Min. Required
Reduction
0.5NTU
_> 99.95%
_> 99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.04mg/L
0.075mg/L
0.003mg/L
Operating
Specifications
• Capacity: certified for up to 300 gallons (1135 I);up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
• Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
• Temperature: 33-100°F (0.6-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 3 minutes to purge out trapped air.
• Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.
Special Notices
• Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
• The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
• Check for compliance with the state and local laws and regulations.
• Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must
be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified bg NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cast and Asbestos Reduction
Manufactured
for: General
Electric
Company,
Louisville,
KY 40225
EPA EST. No. 070595-MN-001
B5