Omron M6 Comfort Instruction Manual

Omron M6 Comfort Instruction Manual

Digital automatic blood pressure monitor
Hide thumbs Also See for M6 Comfort:

Advertisement

Digital Automatic Blood Pressure Monitor
Model M6 Comfort
• Instruction Manual
• Mode d'emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
• РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
IM-HEM-7000-E-01-05/06
EN
FR
DE
IT
ES
NL
RU

Advertisement

Table of Contents
loading

Summary of Contents for Omron M6 Comfort

  • Page 1 Digital Automatic Blood Pressure Monitor Model M6 Comfort • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing • РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ IM-HEM-7000-E-01-05/06...
  • Page 2: Table Of Contents

    Contents Introduction ................3 Important Safety Information ..........4 1. Overview ................5 2. Preparation ................7 2.1 Installing/Replacing the Batteries........7 2.2 Setting the Date and Time ..........8 3. Using the Unit..............10 3.1 How to Sit Correctly When Taking a Measurement ..10 3.2 Applying the Arm Cuff ............12 3.3 Taking a Reading............15 3.4 Instructions for Special Conditions.........18 3.5 Using the Memory Function ...........19...
  • Page 3: Introduction

    Introduction The OMRON M6 Comfort is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the devices uses its advanced “IntelliSense”...
  • Page 4: Important Safety Information

    Important Safety Information • Blood pressure measurement is not suitable in cases of serious arteriosclerosis (hardening of the arteries). • The pulse display is not suitable for monitoring the frequency of cardiac pacemakers. • Pregnant women should only measure their own blood pressure in consultation with their doctor, since the readings can be changed by pregnancy.
  • Page 5: Overview

    1.Overview 1. Overview Monitor A. Display E. Battery compartment B. O/I START button F. Air jack C. Memory ( ) buttons G. AC adapter jack (for optional AC adapter) D. Date/Time ( ) setting button...
  • Page 6: Package Contents

    1.Overview Display H. Systolic blood pressure O. Heartbeat symbol I. Diastolic blood pressure 1. Flashes during measurement J. Memory symbol 2. If flashing after measurement complete indicates blood K. Average value symbol pressure out of recommended L. Movement error symbol range M.
  • Page 7: Preparation

    2.Preparation 2. Preparation Installing/Replacing the Batteries Remove the battery cover. Insert four “AA” batteries as indicated in the battery compartment and then replace the battery cover. Notes: • If the battery low symbol ( ) appears on the display, replace all four batteries at the same time.
  • Page 8: Setting The Date And Time

    2.Preparation Setting the Date and Time Your blood pressure monitor automatically stores up to 90 measurements values in its memory and calculates an average reading based on the measurements from the last three readings taken within 10 minutes. • Set the monitor to the correct date and time before taking a measurement for the first time.
  • Page 9 2.Preparation Repeat steps 2 and 3 to set the month and date (day). Repeat steps 2 and 3 to set the hour and minutes for the time. Press the O/I START button when you have finished setting the date and time.
  • Page 10: Using The Unit

    3.Using the Unit 3. Using the Unit How to Sit Correctly When Taking a Measurement You can take a measurement on either your left or right arm. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position. Make sure that the room is not too hot or cold.
  • Page 11 3.Using the Unit Notes: • Correct posture during measurement is necessary to get accurate results. • You should also try to measure your blood pressure at the same time each day. (Within 1 hour after waking up is recommended.) Incorrect Posture •...
  • Page 12: Applying The Arm Cuff

    3.Using the Unit Applying the Arm Cuff You can wrap the cuff either on your right or left arm. • Remove tight-fitting clothing from your upper arm. • Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight.
  • Page 13 3.Using the Unit Hold the grip on the cuff securely with Grip your hand. Fabric fastener Turn the palm of your hand upward. Turn the palm of your hand upward. Bottom edge 1 to 2cm Blue strip Air tube Apply the cuff to your upper arm so that the blue strip is centred on the middle of your inner arm and points down the inside of the arm.
  • Page 14 3.Using the Unit When the cuff is positioned correctly, close the fabric fastener FIRMLY. Notes: • Make certain the cuff fits snugly around your arm. • The cuff should make good contact with your skin. You should be able to fit your index finger between the cuff and your arm easily, so you can pull the cuff off and on.
  • Page 15: Taking A Reading

    3.Using the Unit Taking a Reading Press the O/I START button and remain still, the cuff will start to inflate automatically. As the cuff begins to inflate, the monitor automatically determines your ideal inflation level. Remain still and do not talk until measurement is completed.
  • Page 16 3.Using the Unit Press the O/I START button to turn the monitor off. Note: If you forget to turn the monitor off, it will automatically shut itself off after five minutes. Important: • Wait 2-3 minutes before taking another blood pressure measurement.
  • Page 17 3.Using the Unit heart- or circulation-disease) a lower limit of blood pressure might be necessary and that it is recommended to consult the doctor in such cases. What is Irregular Heartbeat? An irregular heartbeat is a Normal Heartbeat heartbeat rhythm that varies Pulse by more than 25% from the average heartbeat rhythm...
  • Page 18: Instructions For Special Conditions

    3.Using the Unit Instructions for Special Conditions If your systolic pressure is known to be more than 220 mmHg, after the cuff starts to inflate, press and hold the O/I START button until the monitor inflates 30 to 40 mmHg higher than your suspected systolic pressure.
  • Page 19: Using The Memory Function

    3.Using the Unit Using the Memory Function This monitor has a memory capable of storing 90 sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate with the date and time. The monitor also calculates an average reading based on the measurements from the last three readings taken within 10 minutes.
  • Page 20 3.Using the Unit To View Previous Readings Stored in Memory Press the button, while the average reading is displayed, to view reading stored in memory from the most recent to the oldest. Alternating display Press the button repeatedly to cycle through the previous measurement values button: from the most recent to the oldest, button: from the oldest to the most recent)
  • Page 21: Quick Reference Guide

    4.Quick Reference Guide 4. Quick Reference Guide To help ensure a reliable reading, avoid eating, smoking, or exercising for at least 30 minutes before taking a measurement. Note: Remove any tight-fitting clothing from your upper arm. Sit on a chair with your feet flat on the floor and place your arm on a table so that the arm cuff will be at the same level as your heart.
  • Page 22: Handling Errors And Problems

    5.Handling Errors and Problems 5. Handling Errors and Problems Error Messages Error Display Cause Remedy Cuff is under inflated. Movement during Carefully read and repeat the steps measurement listed under section 3.3. Cuff over inflated. Remove the arm cuff. Wait 2-3 minutes and then take another This icon indicates irregular measurement.
  • Page 23: Troubleshooting

    5.Handling Errors and Problems Troubleshooting Problem Cause Remedy No display appears when the O/I START The batteries are empty. Replace the batteries. button is pressed. Is the cuff wrapped firmly Attach the arm cuff around the arm? correctly. Cannot measure or The cuff pressure does Check that the air plug is readings are too high.
  • Page 24: Maintenance And Storage

    • The OMRON M6 Comfort is a precision measuring device. It is important that the accuracy remains within the specifications. It is recommended that you have the monitor inspected every two years to ensure it is accurate and functioning correctly.
  • Page 25: Optional Parts

    7.Optional Parts 7. Optional Parts AC Adapter (Q-adapter) Arm Cuff Order No. 1098336-8 Order No. 9956685-4 Using the Optional AC Adapter Insert batteries into the battery compartment even when using the AC adapter. Notes: • Never unplug the power cord with wet hands. •...
  • Page 26: Technical Data

    8.Technical Data 8. Technical Data Product Description Digital Automatic Blood Pressure Monitor Model OMRON M6 Comfort (HEM-7000-E) Display LCD Digital Display Measurement Method Oscillometric method Pressure: 0 mmHg to 299 mmHg Measurement Range Pulse: 40 to 180/min. Pressure: ±3 mmHg Accuracy Pulse: ±...
  • Page 27: Correct Disposal Of This Product

    Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter. Further documentation in accordance with IEC60601-1-2:2001 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com. Correct Disposal of This Product (Waste Electrical &...
  • Page 28: Some Useful Information About Blood Pressure

    9.Some Useful Information about Blood Pressure 9. Some Useful Information about Blood Pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle. The highest pressure in the cycle is called the Systolic Blood Pressure;...
  • Page 29 9.Some Useful Information about Blood Pressure Upper curve: systolic blood pressure Lower curve: diastolic blood pressure Time of day Example: fluctuation within a day (male, 35 years old) Classification of Blood Pressure by the World Health Organization The World Health Organization (WHO) and the International Society of Hypertension (ISH) developed the Blood Pressure Classification shown in this figure.
  • Page 30 9.Some Useful Information about Blood Pressure OMRON HEALTHCARE UK LTD. Subsidiary Opal Drive Fox Milne, Milton Keynes MK 15 0DG, United Kingdom OMRON Medizintechnik Handelsgesellschaft m.b.H. Subsidiary Windeckstraße 81a, D-68163 Mannheim, Germany www.omron-medizintechnik.de OMRON SANTÉ FRANCE Subsidiary 14, rue de Lisbonne, F-93561 Rosny-sous-Bois Cedex, France OMRON HEALTHCARE CO., LTD.

Table of Contents