Maintenance Schedule; General Recommendations - Craftsman 580.675512 Operator's Manual

Ac generator 5600 watt
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCESCHEDULE
Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in
adverse conditions noted below.
* Changeengine oil
* Cleandebris
* Check engine oil level
* Service engine air cleaner'
* Changeengine oil'
* Service spark plug
* Inspect muffler and spark arrester
* Cleancooling system'
* Checkvalve clearance
Service more often under dirty or dusty conditions.
General Recommendations
Regular maintenancewill improve the performance and
extend the life of the generator. See a Sears or other qualified
dealer for service.
The generator's warranty does not cover items that have
been subjected to operator abuse or negligence. To receive
full value from the warranty, the operator must maintain
generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the Maintenance
Schedule chart above.
NOTICE Oncea year you should clean or replace the spark
plug and replacethe air filter. A new spark plug and clean air
filter assure proper fuel-air mixture and help your engine run
better and last longer.
EmissionsControl
Maintenance, replacement, or repair of the emissions con-
trol devices and systemsmay be performedby any non-
road engine repair establishment or individual. However,
to obtain "no charge" emissions control service, the work
must be performed by a factory authorized dealer. See the
Emissions Warranty.
GEHERATOR MAINTENAHCE
Generator maintenanceconsists of keeping the unit clean and
dry. Operateand store the unit in a clean dry environment
where it wiii not be exposed to excessivedust, dirt, moisture
or any corrosive vapors. Cooling air slots in the generator
must not become clogged with snow, leaves,or any other
foreign material.
Check the cleanliness of the generator frequently and clean
when dust, dirt, oil, moisture or other foreign substances are
visible on its exterior surface.
NOTICE DONOT use a garden hose to clean generator.
Water can enter the engine fuel system and cause problems.
In addition, if water enters the generator through cooling air
slots, some of the water will be retained in voids and cracks
of the rotor and stator winding insulation. Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
GeneratorCleaning
Daily or before use, clean accumulated debris from
generator. Keep linkage, spring and controls clean. Keeparea
around and behind muffler free from any combustible debris.
Inspect cooling air slots and openings on the generator.
These openings must be kept clean and unobstructed.
Generator parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris.
*
Use a damp cloth to wipe exterior surfaces clean.
NOTICE Improper treatment of generator can damage it
and shorten its life.
• DO NOT expose generatorto excessive moisture, dust, dirt, or
corrosive vapors.
• DO NOT insert any objects through cooling slots.
*
Use a soft bristle brush to loosen caked on dirt, oil, etc.
*
Usea vacuumcleanerto pick up loosedirt and debris.
17