CORDSETSAND RECEPTACLES
Use only high quality, well-insulated, grounded extension
cords with the generator's 120 Volt electrical receptacles.
Inspect extension cords before each use.
Checkthe ratings of all extension cords before you use them.
Extension cord sets used should be rated for 125 Volt AC
loads at 20 Amps or greater for most electrical devices.
Some devices, however, may not require this type of
extension cord. Checkthe operator's manuals of those
devices for the manufacturer's recommendations.
Keep extension cords as short as possible, preferably less
than 15 feet long, to prevent voltage drop and possible
overheating of wires.
_i, WARNING Overloadedelectrical cords can overheat,
arc, and burn resulting in death, bodily injury,
and/or property damage.
• ONLYusecordsratedfor your loads.
• Followall safetieson electrical c ords.
1201240 Voff AC, 30 Amp, Lockin9 Receptacle
Use a NEiViAL14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater). You can use the same 4-wire cord if you plan to
run a 120 Volt load.
4-WireCordSet
--\
(Neutral)
x/,ot!
NEMA L14-30
7/I-7 Ground(Green)
This receptaclepowers 120/240 Volt AC, 60 Hz, single phase
loads requiring up to 5,600 watts of power (5.6 kW) at
23.3 Amps for 240 Volts or two independent 120 Volt loads
at 23.3 Amps each. The outlet is protected by a double pole
rocker switch circuit breaker.
NOTICE
Receptacles may be marked with rating value
greater than generator output capacity.
• NEVERattempt to power a device requiring more amperage than
generator or receptacle can supply.
• DO NOT overloadthe generator. SeeDon't OverloadGenerator.
1211Voff AC, 20 Amp, DupJexReceptacles
Eachduplex receptacleis protected against overload by a
double pole rocker switch circuit breaker.
Use each receptacleto operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Use cord sets that are rated for 125 Volt
AC loads at 20 Amps (or greater). Inspect cord sets before
each use.
Generator Adapter Cord Set
The generator comes with a 25' generator adapter cord set
designed to provide two sets of 120 Volt, 20 Amp outlets
from one 120 Volt, 20 Amp duplex receptacle.
J
The maximum load on each outlet is 20 Amps. The maximum
total load on both red dot outlets or blue dot outlets is
20 Amps.
NOTICE Follow all safety precautions when connecting any
extension cord or device to the generator.