Performance Data Sheet - GE ESS25XGSBBB Owner's Manual And Installation

Side by side 23 and 25 models
Table of Contents

Advertisement

Available languages

Available languages

Performance Data Sheet
SmartWater
Filtration
System
GWF/ HWF Cartridge
Thissystemhasbeen testedaccording to NSF/ANS142/53for reduction of the substanceslisted below.
The concentrationof the indicated substancesin water entering the systemwas reduced to a concentration
less than or equal to thepermissible limit for water leaving the system,as specified in NSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Standard
No. 42: Aesthetic
Effects
Parameter
Chlorin(
T ,%()
Parti(ulale**
USEPA
MCL
]nfluent
Challenge
Concentration
2.0
mgiL
+ 10 '_:
at ]easl
10,0(,_)
[)m_lk ks/mE
Effluent
Average
Maximum
0.02 ppm
0.05 ppm
3,978
7,800
Stmidard
No. 53: Health
Effects
Parameter
Influent
Effluent
% Rexluclion
Average
Mhfimum
98.90%
97.37!'{
ChMlenge Concentration
Average
Maximmn
Average
'Ihrbidity
11 + 1 NT[ *'::*
0.07 NTI
0.1 NT[
99.71%
Cysts
Minimum 50,0(_) L
26
55
99.97{_
Lead aI ptt 6.5
0.15 mgiI
+ 10%
1 ppb
1 ppb
99.37%
Lead al ptt 8.5
0.15 mgiI
+ 10%
1.8 ppb
4.3 ppb
98.8%
Lindane
0.1,q)2mgiL + 10{:{
0.00005 ppm
0.00005 ppm
91.93%
Atmzine
0.1,q)9mgiL + 10{:{
0.1,q)2ppm
0.003 ppm
76.19%
2,44)
0.210 mgiL + 101:{
0.042 ppm
0.090 ppm
84.89%
A_bestos
10 r to 10*fibep_iL;
0.32 MFLiml
1.2 MFI.iml
99.951_
fibel'_ gwater fllan
10 micrometel'_
in length
Min. Reqtdred
Reduction
> 50%
> 85%
USEPA
MCL
1 NTI ***
{){).95%Reduction
15 ppb
15 ppb
(1.(1(1(12 ppm
0.003 ppm
0.100 ppm
99%
% Reduction
Mitfimum
99.59!_
99.95%
99.37%
97.13%
91.93!_
64.28!_
67.63!_
99.82%
Mhl. Reqtfir_l
Reduction
0.5 NT[ 7
> 99.95!:_
0.010 mgiL
0.010 mgiL
0.01_)2 mg!L
0.(,q)3 mgiL
0.07 mgiI.
99%
Tested using a flow rate of O. 5 gpm; pressure of 60 psig; pH of 7.5 _+O. 5 ; temp. of 20 ° _+2.5°C
_ Measurement in Particles/ml. Particles used were 0.5-1 microns
_
NTU=Nephelometric Turbidity units
Operating Specifications
(_apacit'y:
certified
for
up to 300
galhms
(l 135 1); up to six months
for models
without
a replacement
filter
indicator
light;
up to one
vear
fi)r models
with
a replacelnelK
filter
indicator
light
Pressure
requirenlent:
40-120 psi (2.8-8.2
bar),
non-shock
Temperature:
33-100°F
(0.6-38°C)
Flow
rate:
0.5 gpm
(1.9 lpm)
General Installation/Operation/Maintenance
Requirements
Flush
new
cartridge
at full
flow
for
.3 inilmtes
to Imr°e_
out
trapped
air.
Replace
cartridge
when
flow becolnes
too
slow.
Special Notices
h_stallation
ii_sti uctions,
parts
and
service
availability,
and
standard
warranty
are
ilwluded
with
the
product
when
shipped.
This
drinking
water
s_steln
inust
be inaintained
according
to inanufilcturer's
instluctions,
includii_g
replacelnent
of filter
ca rtridges.
Do
not
use
with
water
that
is microbiologically
unsafe
or of unknown
tluali W without
adequate
disinfection
before
or
alter
the
svsteln,
Svstelns
certified
for
c_:st reductiola
inav
be
used
on disilffected
water
that
inav
contain
filterable
cysts,
The
contanfilmlatS
or other
substances
relnoved
or reduced
by this
water
treatmelat
sx:steln
are
not
necessarily
in your
water.
_ Check
tot
compliance
with
the
state
and
local
laws and
regtdations.
Note
that
while
the
testing
was pertormed
trader
standard
laboratoi
T conditions,
actual
performance
may
w_rv.
Systems
must
be installed
and
operated
in accordance
with
manufacturer's
recommended
procedures
and
gtfidelines.
System "I-(st_d and (2:rtifio:l by NSF Int_ rnational
against ANSI/NSF
Standard
4_ & :
fl)l _ Ih¢
re(hlction
of:
StmMard No. 42: Aesthetic
Effects
(ihemical
Unit
'Ihste and Odor Reduction
Chlorine
Reduction
Mechanical
Fihration
[nit
Partictflate
Reduction,
Class I
Standard No. 53: Health Effects
Chemical
Re(hlction
Unit
I.ead and Atrazine
R(du(tion
Lindane
and 2,4-I[) R( duclion
Medlanical
Filtration
[nit
Tmbiditv
P.eduction
(_}'St
;all({
msb(_slos
1).((lu(tion
Manufa(mred
for: (;¢ neral
Ele(tri(
Company,
Louisville,
K%' 40225
36

Advertisement

Table of Contents
loading