DOH'TOVERLOAD GENERATOR
Capacity
You must make sure your generator can supply enough rated
(running) and surge (starting) watts for the itemsyou will
power at the same time. Follow these simple steps:
1.
Select the itemsyou will power at the same time.
2.
Total the rated (running) watts of these items. This isthe
amount of power your generator must produce to keep
your items running.
3.
Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Becausenot all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Rated
(Running)
Watts
1200
8OO
5OO
5OO
75
3075 Total
Running Watts
Tool or Appliance
Window
Air
Conditioner
Refrigerator
Deep
Freezer
Television
Light (75 Watts)
Total Rated (Running) Watts
HighestAdditional Surge Watts
Total Generator Output Required
Additional
Surge
(Starting)
Watts
1800
1600
5OO
1800
Highest
Surge Watts
= 3075
= 1800
= 4875
NOTE:The rated (running) watts cannot exceed 5600. Also,
given the 5600 watt rated limit, additional surge (starting)
watts cannot exceed 8600.
Power Management
To prolong the life of your generator and attached devices, it
is important to take care when adding electrical loads to your
generator. There should be nothing connected to the
generator outlets before starting it's engine. The correct and
safe way to managegenerator power is to sequentially add
loads as follows:
1.
With nothing connected to the generator, start the
engine as described in this manual.
2.
Plug in and turn on the first load, preferably the largest
load you have.
3.
Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4.
Plug in and turn on the next load.
5.
Again, permit the generator to stabilize.
6.
Repeatsteps 4 and 5 for each additional load.
Rated*
Tool or Appliance
(Running)
Watts
Essentials
Light Bulb - 75 watt
Deep
Freezer
Sump
Pump
Refrigerator/Freezer-
18 Cu. Ft.
Water Well
Pump
- 1/3 HP
Heating/Cooling
Window
AC - 10,000
BTU
Window
Fan
Furnace
Fan Blower
- 1/2 HP
Kitchen
Microwave
Oven - 1000 Watt
Coffee
Maker
Electric
Stove
- Single
Element
Hot Plate
Family
Room
DVD/CD
Player
VCR
Stereo
Receiver
Color Television
- 27"
Personal
Computer
w/17"
monitor
Other
Security
System
AM/FM
Clock
Radio
Garage
Door Opener-
1/2 HP
Electric
Water
Heater
- 40
Gallon
DIY/Job
Site
Quartz
Halogen
Work
Light
Airless
Sprayer
- 1/3 HP
Reciprocating
Saw
Electric
Drill - 1/2 HP
Circular
Saw - 7 1/4"
Miter
Saw - 10"
Table
Planer
- 6"
Table Saw/Radial
Arm Saw - 10"
Air Compressor
- 1-1/2 HP
75
5OO
8OO
8OO
1000
Additional
Surge
(Starting)
Watts
5OO
1200
1600
2000
1200
1800
300
600
800
1300
logo
15oo
15oo
2500
log
log
45o
5oo
8oo
180
300
48O
4000
1000
60O
96O
1000
1500
1800
1800
2000
2500
520
1200
960
1000
1500
1800
1800
2000
2500
NEVERadd more loads than the generator capacity. Take
special care to consider surge loads in generator capacity, as
described above.
*Wattageslisted are approximate only. Checktool or
appliance for actual wattage.