Frigidaire FRS124YW10 Use & Care Manual page 22

Split system
Table of Contents

Advertisement

Connect the cable to the outdoor unit
1.
Remove the electrical control
board cover from the outdoor unit
by loosening the screw.
2. Connect the connective cables to
the terminals as identified with
their respective matched numbers
on the terminal block of indoor
and outdoor units. The connective
cable to power supply shall be
approved polychloroprene
sheathed flexible cord, type
designation 12AWG
or heavier cord.
3. Secure the cable onto the control
board with the cord clamp.
4.
To prevent the ingress of water,
form a loop of the connective
cable as illustrated in the
installation diagram of indoor and
outdoor units.
5. Insulate unused cords (conductors)
with PVC-tape. Process them so
they could not touch any electrical
or metal parts.
Cable
Code wire
Terminal
b!ockof
outdoor
unit
To indoor unit
To power
supply

Advertisement