Craftsman 919.167710 Owner's Manual page 15

Permanently lubricated single stage portable
Hide thumbs Also See for 919.167710:
Table of Contents

Advertisement

Available languages

Available languages

Before Each Start=Up
1.
Place Auto/Off switch to "Off".
2.
Pull regulator knob out, turn
counter-clockwise
until it stops.
Push knob in to lock in place.
3.
Attach hose and accessories.
NOTE: The hose or accessory will
require a quick connect plug if the
air outlet is equipped with a quick
connect.
_Risk
of unsafe
--
operation.
Firmly
grasp air hose in hand when
installing or disconnecting
to
prevent hose whip.
Risk of unsafe
operation,
Do not
use damaged
or worn accessories.
_Too
much air
__
pressure causes a
hazardous
risk of bursting. Check
the manufacturer's
maximum
pressure rating for air tools and
accessories.
The regulator
outlet
pressure must never exceed the
maximum
pressure
rating.
Risk of unsafe
operation.
Compressed air from the unit may
contain water condensation
and
oil mist. Do not spray unfiltered air
at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered air.
Read the instructions for the air tools
and accessories.
Bow to Start
1.
Turn the Auto/Off switch to
"On/Auto" and allow tank pres-
sure to build. Motor will stop
when tank pressure reaches "cut-
out" pressure.
2.
Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
Risk of fire or
' "-
_--explosion.
AIways
operate the air compressor in well-
ventilated areas free of gasoline or
other combustible
vapors. If the
compressor is being used to operate a
sprayer DO NOT place near the spray
area.
_lf
any unusual
__
noise or vibration
is noticed,
stop the compressor
immediately and have it checked
by
a trained service technician.
The compressor
is ready for use.