Heating Control; Fan Cycle Switch; Vent Control - Friedrich TEC12K34 Installation & Operation Manual

Table of Contents

Advertisement

Heating
Control
NOTE: Heat pump models only. Heat pump equipped models use
backup electric resistance heating coils. At extremely low outdoor
ambient temperatures, the heat pump is automatically disabled and the
unit operates solely on electric resistance heat.
The heating control is located behind the front panel at the control box
bottom and is accessible through the return air louver opening. Its
function is to allow you to set the temperature range in which the heat
pump operates. This control switches the unit heat operation between
heat pump and electric resistance heat based on the outdoor ambient
temperature. These change over temperatures are based on the
settings of this control. In most cases, the factory setting (at approxi-
mately the one o'clock position) is adequate.
If you wish to change the
OMP6"
04'Z_
O
r"_
EM_RGENC'¢
HEAT
CHAUFFAGE
D'UR_ENCE
DE EME_GENCIA
HEATING
CONTROL
COMMANDE
DE CHAUFFAGE
CONTROLDELCALOR
factory set point, insert a flat bladed screwdriver into the slot and turn counterclockwise
to increase the changeover set
point.
In the event of a compressor malfunction, turn the screw to the extreme counterclockwise
emergency heat position. The
heater will then cycle using electric resistance heat only. Note that in the emergency heat position, the compressor is locked
out, disabling both heat pump and cooling operations. CALL A SERVICE PERSON.
Fan Cycle
Switch
CYCLE DU
VENTILATEUR
CICLO DEL
VENTILADOR
m
CONTINUOUS
FAN
CYCLE
CYCLE
CICLO
The fan cycle switch is located behind the front panel at the bottom of the
control box. It is accessible through the return air louver opening.
It is
designed to operate the fan either continuously or intermittently with the
compressor or heating elements.
When the switch is in the CONTINU-
OUS position, the fan will run continuously when the power switch is on.
With the fan cycle switch in the CYCLE position, the fan will run only when
the compressor or heating elements cycle on.
I
NOTE:
For maximum
comfort
and temperature
control,
it is
=
recommended
that this switch be set in the continuous position.
I
Vent Control
OPEN
OUVERT
ABIERTA
VENT
AERATION
SALIDA
(ESCAPE)
DEL AIRE
CLOSED
FERM_
CERRADA
The vent control lever is located behind the front panel at the bottom of the
control box. When the lever is up, (OPEN), outside air is mixed with indoor
air. When the lever is down, (CLOSED), no outside air is admitted into
room and room air is recycled through unit.
I
NOTE: For peak operating efficiency the vent should remain closed.
I
....
711

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents