For The Electrician - Whirlpool 50 Installation Instructions Manual

Table of Contents

Advertisement

For the
electrician
Electrical requirements
A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical
supply is required (time delay fuse or circuit breaker
is recommended).
It is recommended
that a separate
circuit, serving only this appliance,
be provided.
DO
NOT use an extension
cord.
ELECTRICAL
GROUND
IS REQUIRED
ON THIS
APPLIANCE.
Recommended
grounding methods
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
For your personal
safety,
this appliance
must be
grounded.
This appliance
is equipped
with a power
supply
cord having
a 3-prong
grounding
plug. To
minimize
possible
shock hazard, the cord must be
plugged
into a mating 3-prong grounding
type wall
receptacle, grounded in accordance with the National
Electrical Code and local codes and ordinances.
If a
mating wall receptacle is not available, it is the personal
responsibility
and obligation
of the customer to have
a properly grounded 3-prong wall receptacle installed
by a qualified
electrician.
See Figure 6.
3-PRONG
GROUNDING
TYPE
WALL
RECEPTACLE
NG
NDING
POWER
SUPPLY
CORD
Alternate
grounding method
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
If changing and properly grounding the wall receptacle
is impossible
and where local codes permit (consult
your electrical inspector), a temporary adapter may be
plugged
into the existing
2-prong wall receptacle
to
mate with the 3-prong power supply cord. See Figure
7. THIS, HOWEVER,
IS NOT RECOMMENDED.
If this is done, you must connect the grounding
eyelet
on the adapter to the wall receptacle cover plate screw
and from this same screw, you must connect a separate
copper ground wire (No. 4 minimum) to a grounded cold
water pipe*. See Figure 7. Do not ground to a gas supp-
ly pipe. Do not connect to electrical
supply until ap-
pliance is permanently
grounded.
*Cold water pipe must have metal continuity
to elec-
trical ground and not be interrupted
by plastic, rubber
or other electrically
insulating
connectors
(including
waler meter or pump) without adding a jumper wire at
these connections.
GROUND
ASSEMBLY
(ATTACH
TO GROUNDED
COLD
WATER
PIPE)
ELECTRICALLY
GROUNDED
COLD
WATER
PIPE (REMOVE
GROUND
WIRE
(##4 MINIM
3-PRONG
GROUNDING
PLUG
ASSEMBLY
WALL
RE
POWER
SUPPLY
CORD
t-
ICEPTACLE
FIGURE 6
FIGURE 7
5