For The Electrician - Whirlpool 3EHC 50/51-1 Use, Care & Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

NOTE: Always purge the water line before making
the final connection
to the inlet tube to prevent
possible
water valve malfunction.
After the cabinet
is in place, bend the tubing
to
meet the connection
at the water valve. This joint
provides
a convenient
disconnect
for service.
Be
sure the tubing
is clear of compressor,
to prevent
rattle.
2
5
RIGHT END VIEW
BACK VIEW
CABINET
5.35 mm 0.0. WATER
LINE COMPRESSION
FllTlNG
AT
WATER INLET
VALVE
1
HOLE FOR FIELD
5"PPlEO
WATER
WATER LINE TO CONNECT
TO WATER VALVE FIlTING
mm
4
FIGURE
1
CONNECT
THE DRAIN
1.
2.
3.
The unit is provided
with a gravity drain.
The ideal installation
has a standpipe
(32 mm,l%"
minimum)
installed
directly below the outlet of the
drain tube.
It may
be desirable
to
insulate
drain
line
thoroughly
up to drain inlet.
SUMP PUMP
1. When a drain connection
below the level of the unit
is not available, a sump pump may be used to lift the
water to an available drain.
2. Pumps of approved design for operation
on 220/240
Volt, 50 Hz current may be purchased
locally.
3. Install sump pump on floor behind ice maker with
discharge
tube to the rear. Run bin drain directly to
sump pump as shown in the illustration.
1
SVMP PUMP HAS FLOAT
SWlTCn THAT CYCLES
2
A00
PLASTIC
HOSE
3
FIELDSUPPLIED
WATER
LINE
THRU
THIS HOLE
NOTE: Electric connection
to sump pump should
be from a circuit that remains energized continually.
FOR THE ELECTRICIAN
ELECTRICAL
REQUIREMENTS
A 220/240 Volt, 50 Hz, 10 Amp fused electrical supply is
required
(time delay fuse or circuit
breaker is recom-
mended).
It is recommended
that a separate circuit,
serving only this appliance
be provided.
ELECTRICAL
GROUND IS REQUIRED ON
THIS MACHINE
GROUNDING
For your personal safety permanently
ground this unit
in accordance
with applicable
local codes and ordi-
nances. It is recdmmended
that a separate, permanent
ground connection
be made to the unit using a green/
yellow colored, insulated conductor
of appropriate
size
from a grounded
cold water pipe*, a grounded
lead in
the service panel or a properly
driven and electrically
grounded
ground
rod. Do not ground to a gas supply
pipe. Do not connect to electric power supply until unit
is permanently
grounded.
Connect the ground wire to
the approved
ground
and then connect
to the metal
frame of the unit.
'Cold water pipe must have metal continuity
to electrical
ground
and not be interrupted
by plastic.
rubber,
or other
electrically
insulating
connectors
(including
water
meter or pump)
without
adding a jumper
wire at these connections.
WIRING
CONFORM
TO ALL LOCAL CODES
AND ORDINANCES
Remove grill mounting
screws for access to motor com-
partment
and water connections.
Electrical
connec-
ticns are made to the electrical
box which is located at
the rear of the machine. Run permanent
type 1.6 mm +
(# 14) wiring through the hole provided in the electrical
box to the line screws on the terminal board. (See figure
2 next page.)