Advertisement

Quick Links

\
c
ICE MAKER
Model 50
-_I,
., .
; / i,&.rT+.~-:-
* .":*,
-A:',:.
~"~~$i+&~~,~-~~~~
'..*...;?&
\*l?~.<.'.
,.. _ -.:T.$z.*:
.>a : k ~;P-f&-.;'~.-&p&+~~.~
:~ ;- ~,,
_, .' ;G.,;;,.
::? : ,:i
i'.
:
:
-
* 'Al *;, &!g
;'p$c**,;
:; :,
" ,
--;.
ave Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwas

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool 50

  • Page 1 ICE MAKER Model 50 -_I, ., . ; / i,&.rT+.~-:- * .“:*, -A:‘,:. ~“~~$i+&~~,~-~~~~ ‘..*...;?& \*l?~.<.‘. ,.. _ -.:T.$z.*: .>a : k ~;P-f&-.;‘~.-&p&+~~.~ :~ ;- ~,, _, .‘ ;G.,;;,. ::? : ,:i i’. * ‘Al *;, &!g ;‘p$c**,; :; :, ”...
  • Page 2: Changing The Bin Door Panel

    Changing the bin door Thermostat calibrations panel If ice maker is installed above two thousand feet of altitude, the bin and evaporator thermostats must be adjusted to a warmer setting. Disconnect electricity, The storage bin door is designed to accept an optional remove thermostat and follow the directions for turn-...
  • Page 3: For The Plumber

    ,.>, ._;,- . . - . . - . ; 2. Area should be well ventilated with temperature 4. Remove all tape and packaging material from the above 55OF and below 11 OOF. Best results are ob- outside and inside of the cabinet. See Figure 4. tained between 7O’JF and 9OOF.
  • Page 4: Machine Controls

    FIGURE 5 RIGHT END VIEW BACK VIEW -17.7/w*- WATER INLET SOLENOID VALVE 4” LONG 5/8” I.D. RUBBER 34-13132 DRAIN TUBE - RUN TO 7.112” HOLE FOR FIELD -Lt- SUPPIED WATER BEND FIELD SUPPLIED WATER LINE TO CONNECT TO WATER VALVE FITTING l-1/2”...
  • Page 5: For The Electrician

    For the Alternate grounding method electrician DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. Electrical requirements If changing and properly grounding the wall receptacle A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical is impossible and where local codes permit (consult supply is required (time delay fuse or circuit breaker your electrical inspector), a temporary adapter may be...
  • Page 6 How it works As the room and water temperatures vary, so will the amount of ice produced. This means that higher . Compressor runs operating temperatures will result in reduced ice production. 9 Condenser fan runs The unit will shut off when ice in the storage bin Water pump runs (circulates water) touches the bin thermostat well and will automatical-...
  • Page 7 Unit wiring diagram CUBELET CUTTER GRIDS This model operates at 115 volts except for the cutter grid circuit which operates at 8.5 volts at 1 amp. The compressor runs at all times except when the bin thermostat becomes satisfied and opens up. This de- energizes the system except for the transformer cutter grid.
  • Page 8: Home .% Appliances

    HOME .% APPLIANCES Making your world a little easier. In the event your WHIRLPOOL appliance should need service, call dealer from whom purchased @ service company. is in the Yellow Pages of your appliance or a WHIRLPOOL franchised TECH-CARE telephone directory listed under...

Table of Contents