6.
After 20 minutes, close the drain
valve (clockwise). The air receiver
wilI fill to "cut-out"
pressure and
the motor wilI stop.
The compressor is now ready for use.
Before
Each
Start-Up:
1.
Place On/Auto/Off
lever to "Off".
2.
Pull regulator knob out, turn
counterclockwise
until it stops,
Push knob in to lock in place,
3.
Attach hose and accessories,
NOTE: The hose or accessory
will require a quick connect ptug
if the air outlet is equipped with a
quick connect.
Risk of Bursting,
Too much air
pressure
causes a hazardous
risk of bursting,
Check the
manufacturer's
maximum
pressure
rating for air tools and accessories,
The reguBator outlet pressure
must never exceed the maximum
pressure
rating,
Bow
to Start:
1.
Turn the On/Auto/Off
lever
to "On/Auto" and allow tank
pressure to build.
Motor will
stop when tank pressure reaches
"cut-out"
pressure.
2.
PulI the regulator knob out
and turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
A09713