Download Print this page
Craftsman 919.153160 Owner's Manual
Craftsman 919.153160 Owner's Manual

Craftsman 919.153160 Owner's Manual

Permanently lubricated tank mounted air compressor

Advertisement

Available languages

Available languages

Quick Links

Owner's
Manual
I CRAFTSMFINI
Permanently
Lubricated
Tank Mounted
AiR COMPRESSOR
=
Safety Guidelines
=
Assembly
=
Operation
=
Maintenance
=
Service
and Adjustments
=
Troubleshooting
=
Repair
Parts
CAUTION;
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
1000002888
R_v. 0 6/18/07

Advertisement

loading

Summary of Contents for Craftsman 919.153160

  • Page 1 Safety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts CAUTION; Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman 1000002888 R_v. 0 6/18/07...
  • Page 2 WARRANTY ..........SPECiFiCATiON CHART ........SAFETY GUiDELiNES = DEFiNiTiONS ......iMPORTANT SAFETY iNSTRUCTiONS ......GLOSSARY ..........ACCESSORIES ..........DUTY CYCLE ..........ASSEMBLY ..........iNSTALLATiON ......... 10-11 OPERATION ..........12-14 MAINTENANCE ......... 14-15 SERVICE AND ADJUSTMENTS ......15-16 STORAGE ..........TROUBLESHOOTING ........
  • Page 3: Glossary

    Model No. "919.153160 Running HP Bore 1-7/8" Stroke 1- 1/4" Voltage-Single Phase 120V Minimum Branch Circuit Requirement 10 amps Fuse Type Time Delay Air Tank Capacity 6 gallon Approx. Cut-In 120 PSI Approx. Cut-out 150 PSI SCFM @ 40 PSIG *3.7 SCFM @ 90 PSIG *2.6...
  • Page 4 not operate this unit until you read and understand this instruction manual for safety, operation and maintenance instructions. SAVE THESE iNSTRUCTiONS RISK OF EXPLOSION OR FiRE WHAT CAN HAPPEN NOW TO PREVENT iT It is normal for electrical contacts • •...
  • Page 5 RISK TO BREATHING (ASPHYXiATiON) WHAT CAN HAPPEN HOW TO PREVENT iT The compressed air directly from Air obtained directly from the com- your compressor is not safe for pressor should never be used to breathing. The air stream may con- supply air for human consumption.
  • Page 6: Accessories

    • Modifications or attempted repairs Never drill into, weld, or make any to the air tank. modifications to the air tank or its attachments. Never attempt to repair a damaged or leaking air tank. Replace with a new air tank. Unauthorized modifications to The air tank is designed to the safety valve or any other...
  • Page 7 • Electrical Grounding: Failure to Make certain that the electrical provide adequate grounding to circuit to which the compressor this product could result in serious is connected provides proper injury or death from electrocution, electrical grounding, correct voltage Refer to "Grounding Instructions" and adequate fuse protection.
  • Page 8 • Attempting to operate compressor Any repairs required on this product with damaged or missing parts or should be performed by authorized attempting to repair compressor service center personnel. with protective shrouds removed can expose you to moving parts and can result in serious injury. RISK OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT iT...
  • Page 9: Duty Cycle

    RiSK FROM NOISE Under some conditions and dura- Always wear certified safety equip- tion of use, noise from this product merit: ANSI $12.6 ($3.19) hearing WHAT CAN HAPPEN • HOW TO PREVENT iT may contribute to hearing loss. protection. SAVE THESE INSTRUCTIONS FOR FUTURE Become familiar with these terms continue to use your accessory.
  • Page 10 Unpacking Remove unit from carton and discard all packaging. Make sure the outlet being used HOW TO SET UP YOUR UNIT has the same configuration as the Location of the Air Compressor grounded plug. DO NOT USE AN ADAPTER. See illustration. •...
  • Page 11 Extension Cords Voltage and Circuit Protection If an extension cord must be used, be Refer to the specification chart for the sure it is: voltage and minimum branch circuit requirements. • a 3-wire extension cord that has a 3-blade grounding plug, and a _Risk of Opertion.
  • Page 12 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. controlled by the regulator and is Description of Operation Become familiar with these controls...
  • Page 13 Check Valve: When the air Open the drain valve (counter- compressor is operating, the check clockwise) fully to permit air to valve is "open", allowing compressed escape and prevent air pressure air to enter the air tank. When the build up in the air tank during the air compressor reaches "cut-out"...
  • Page 14 How to Start: any unusual noise or vibration Set the On/Off switch to "On" is noticed, stop the compressor and allow tank pressure to build. immediately and have it checked by Motor will stop when tank pressure a trained service technician. reaches "cut-out"...
  • Page 15 NOTE: If drain valve is plugged, _Risk of Property Damage. Drain release all air pressure. The valve water from air tank may contain can then be removed, cleaned, the and rust which can cause stains. reinstalled. After the water has been drained, close the drain valve.
  • Page 16 Remove the hose by removing the hose clamp. NOTE: The hose Pump shown clamp is not reusable. You must moved purchase a new hose clamp, the way see the Parts List or purchase a standard hose clamp at a local hardware store.
  • Page 17 _Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 18 PROBLEM CORRECTION CAUSE It is normal for "some" If there is an excessive Pressure reading on the regulated pressure )ressure drop to occur. amount of pressure drop gauge drops when an when the accessory accessory is used. is used, adjust the regulator following the instructions in the "Description of...
  • Page 19 PROBLEM CAUSE CORRECTION Regulator will not shut Damaged regulator. Replace. off air outlet. Motor will not run. Check fuse box Fuse blown, circuit for blown fuse and breaker tripped. replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your...
  • Page 20 Air Compressor Model Number 919.153160 PARTS SHOWN FOR REFERENCE ONLY 1000002888 Compressor _ MODEL NUMBER 919.15316 05/07TS 1000002888 20-ENG...
  • Page 21 Air Compressor Model Number 919.153160 ITEM PART DESCRIPTION D24721 Isolator Kit 91895680 Screw SSF-621 Screw A14877 Nipple A06891 Drain Valve A17987 Safety Valve 1000000273 Manifold (Incl. 5) D20675 Quick Connect Body Z-D21929 Gauge A19714 Check Valve CAC-1254 Pump Isolator LA-3109 Drain Tank Warning Label LA-3108 Hot Surface Label...
  • Page 22 Air Compressor Model Number 919.153160 1000002888...
  • Page 23: Assembly

    Air Compressor Model Number 919.153160 ITEM PART DESCRIPTION 101 1000002791 Shroud (Right) 102 1000002792 Shroud (Left) 103 D25877 Head 104 CAC-1212 Seal 105 D22253 Outlet Tube 106 D30139 Gasket Kit (Incl. 104) 107 Z-A08548 Valve Plate Assembly 109 Z-A04615 Pump 110 AC-0815 Timing Belt e113 SUDL-9-1...
  • Page 24 GARANTiA ............CUADRO DE ESPEClFICACIONES ........DEFINICIONES DE NORMAS DE SEGURIDAD ......IMPORTANTES INSTRUCCIONES DE SEGURIDAD ....25-31 GLOSARIO ............ACCESORIOS ............ ClCLO DE SERVlClO ..........ENSAMBLAGE ............ INSTALACION ..........32-33 OPERACION ........... 34-36 MANTENIMIENTO ..........36-37 SERVlCIOS Y REGULACIONES ........
  • Page 25 Modelo N° "919.153160 0,8 HP Potencia de trabajo DiAmetro interior 1-7/8 pulg. (47,6 mm) Carrera 1-1/4 pulg. (31,8 mm) 120V Voltaje-corriente manof_sica Circuito minimo requerido Acci6n retardada Tipo de fusible Capacidad de aire en el tanque 6 Galones (22,7 litros) Presi6n de corte de entrada 120 PSi Presi6n de corte de salida...
  • Page 26 CONSERVE ESTAS |NSTRUCCIONES RIESGO DE EXPLOSION O INCENDIO _,QUE PUEDE SUCEDER? COMO EVITARLO • Es normal que los contactos el_ctricos • Opere siempre el compresor en un dentro del motor y el interruptor de _rea bien ventilada libre de materiales presi6n produzcan chispas, combustibles, gasolina o vapores de...
  • Page 27 Los materiales pulverizados come pin- Trabaje en un Area con buena venti- tura, solventes para pinturas, remove- laci6n cruzada. Lea y siga las instruc- dor de pintura, insecticidas y herbici- ciones de seguridad que se proveen das pueden contener vapores da_inos en la etiqueta o en la ficha tecnica y venenos, de los materiales que esta utilizando.
  • Page 28 Neum_ticos: El inflado excesivo de los neumati- Utilice un medidor de presi6n de cos podria causar lesiones graves neumAticos para controlar la presi6n y daSo a la propiedad. de 6stos antes de cada uso y mientras los infla; observe el flanco para vet la presi6n correcta del neum_tico.
  • Page 29 RIESGO DE OBJETOS DESPEDIDOS COMO EVITARLO _,QU_: PUEDE SUCEDER? La corriente de aire comprimido Utilice siempre equipo de seguridad certificado: anteojos de seguridad puede provocar lesiones en los ANSI Z87.1(CAN/CSA Z94.3) con pro- tejidos blandos de la piel expuesta tecci6n lateral al usar el compresor. y puede impulsar suciedad, astillas, Nunca apunte ninguna boquilla ni pul- part[culas sueltas y objetos peque-...
  • Page 30 RIESGO DE OPERACION INSEGURA _QU¢: PUEDE SUCEDER? COMO EVITARLO " La operaci6n insegura de su corn- Revise y comprenda todas las instruc- presor de aire podrfa producir lesiones ciones y advertencias de este manual. graves o la muerte, a usted mismo o a Familiarfcese con la operaci6n y los otras personas, controles del compresor de aire.
  • Page 31 tanque baja al valor fijado en fabrica como Familiarfcese con los siguientes punto bajo, el motor volverA a arrancar terminos, antes de operar la unidad: autom_ticamente. La presi6n baja a la cual CFM: (Cubic feet per minute) Pies cObicos el motor arranca automaticamente, se llama por minuto.
  • Page 32 Desempaque Extraiga la unidad de su caja y descarte todas las partes de embalaje. come PREPARAR LA UNIDAD AsegOrese que el tomacorriente tenga la misma configuraci6n que el enchufe de conexi6n a tierra. NO UTILICE UN Ubicaci6n del compresor de aire ADAPTADOR.
  • Page 33 Cables de extensi6n el_ctrica Protecci6n del voltaje y del circuito Si - no obstante - debe utilizarse una exten- Refi@ase a la cartilla de voltajes para si6n de cable, aseg@ese de que: determinar los requisites minimos que el • La extensi6n electrica de 3 conduc- ramal del circuito requiere.
  • Page 34 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para ref- erencias futuras.
  • Page 35 V_lvula de retenci6n: Cuando el com- Abrir per completo (contra el sentido presor de aire se encuentra funcionando, del reloj) para dejar escapar aire y evi- la v_lvula de retenci6n est_ "abierta", per- tar que la presi6n del tanque aumente mitiendo la entrada del aire comprimido durante el periodo de asentamiento.
  • Page 36 C6mo porter en marcha: Riesgo.d.e operation Coloque el interruptor en la posici6n insegura. El aire eomprimido de la de "encendido" (I) y deje que se incre- unidad puede contener condensaci6n mente la presi6n del tanque. El motor se de agua y emanaci6n de aceite.
  • Page 37 Tire del are de la v_lvula de seguridad Riesge de da_o a la dejando purgar el aire del tanque hasta prepiedad. Drene el que este reduzca su presi6n aproxima- agua del tanque de aire puede contener damente a 20 PSI. Suelte el are de la aceite y 6xido, Io que puede provecar rnanchas.
  • Page 38 Saque la manguera quitAndole la Saque la bomba de sus soportes desl- abrazadera. NOTA: La abrazadera izAndola cuidadosamente. no es reutilizable; debe comprar otra nueva. Refi@ase a la Lista de Piezas en el Manual o compre una abrazadera Se muestra estAndar para manguera en una ferret- con la bomba erfa local.
  • Page 39 Riesgo de Operaci6n Insegura. La unidad arranca autom&ticamente cuando est_ enchut'ada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el compresor del tomacorriente, drenar la presi6n de aire del tanque y esperar a que...
  • Page 40 PROBLEMA CORRECCI()N CAUSA Si hubiese una caida exce- La lectura de la presi6n Es normal que ocurra algLin sobre un man6metro desci- descenso en la presi6n. siva de presi6n durante el ende cuando se utiliza un uso del accesorio, ajuste el accesorio.
  • Page 41 PROBLEMA CORRECCJON CAUSA El motor no funciona. Fusible fundido; interrup- Veriflque la caja de fusibles tor autom_tico del circuito observando laexistencia de disparado. fusibles fundidos y sustitt_yalos en caso de necesidad. Restablezcael interruptor automatico. No use un fusible o interruptorautornaticocon valores que excedan los especificados para la rama de su circuito.
  • Page 42 10000028888...
  • Page 43: Installation

    Felicitaciones per hacer una compra Your new Craftsman ® product is designed inteligente. Su nueva unidad Craftsman @ est& manufactured for years of dependable operation. disehada y fabricada para ahos de operacion But like all products, it may require preventive confiable;...
  • Page 44 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances...