Service And Adjustments - Craftsman 919.167341 Owner's Manual

Permanently lubricated single stage portable air compressor

Advertisement

Available languages

Available languages

d:{ollJ :| il ::F,."] -" [oIo]l III _[I
Risk of Unsafer Operation. Performing repairs may expose
voltage sources, moving parts, or compressed
air sources.
Personal injury may occur. Before servicing: Unplug or disconnect
electrical supply to the air compressor, bleed tank of pressure, and allow
the air compressor to cool.
PROBLEM
Excessive tank
pressure - safet
valve pops off.
Air leaks at
fittings.
Air leaks at or
inside check
valve.
CAUSE
Pressure switch does not
shut off motor when
compressor
reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
Air leaks at
Defective pressure switch
pressure switch
release valve.
release valve.
Defective air tank.
Air leaks in air
tank or at air
tank welds.
CORRECTION
Move On/Auto/Off
lever to
the "OFF" position,
if the
unit does not shut off contact
a Trained Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check
fittings with soapy water
solution. Do Not
Overti_hten.
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor is
shut off. Replace check
valve. Refer to the "To
Replace or Clean Check
Valve" in the "Service and
Adjustment"
section.
Contact a Trained Service
Technician.
Air tank must be replaced.
Do not repair the leak.
Risk of
Bursting.
Do not drill into, weld or
otherwise modify air tank
or it will weaken. The tank
can rupture or explode.
Air leaks
Leaking seal.
Contact a Trained Service
between head
Technician.
and valve plate.
21_ENG
D27741