Know Your Generator - Craftsman 919.679470 Owner's Manual

120/240 volt-4750 watt generator
Hide thumbs Also See for 919.679470:
Table of Contents

Advertisement

iMPORTANT:
Before any attempt to start your generator
be sure to check engine oil (See OPERATION under
Adding Engine Oil on page 11)
GROUNDRNG
THE GENERATOR
This generator should be grounded to help prevent
accidental electrical shock. Shown below is a picture of
the grounding lug supplied on your generator. First, drive
a 3/4" or 1" diameter copper pipe or rod into the ground
close to the generator seL The pipe must penetrate moist
earth. Using #10 gauge wire, connect one end of the wire
into the grounding lug. Next, connect the other end of the
wire to the copper pipe or rod using an approved ground
clamp.
Grounding
Lug
KNOW YOUR GENERATOR
Read this Owner's ManuaJ and Safety RuJes be-
fore operation
of your Generater,
Compare this
illustration with your generator to familiarize yourself
with the location of various controls and adjustments.
Save the manual for future references.
FUEL TANK- Capacity of 7 US gallons.
OHOKE SWITCH-
Lever used to start cold engine.
ENGINE
RUN/STOP
SWITCH-
Sets engine in starting
mode for recoil starter - Stops running engine.
ENGINE OiL FILL- Place where engine oil is poured.
OIROUIT BREAKER= Each receptacle has a circuit
breaker to protect the generator from overloading.
120 VOLT REOEPTAOLES-
Used to supply 2350 watts of
electrical power per receptacle for operations.
Protected
by 15 amp circuit breaker.
240 VOLT RECEPTACLES-
Used to supply 4700 watts
of electrical power per receptacle for operations. Wiii
only supply 2350 watts each if both receptacles are
being used. Protected by 20 amp circuit breaker.
AiR CLEANER- Includes filter element and foam
pre-cleaner that limits the amount of dirt that enters
FUELCAP
120 VOLT RECEPTACLES
240 VOLT RECEPTACLES
ENGINE O_L F_LL
ENGINE RUN/STOP
SWITCH
9 -- ENG