Craftsman 919.679470 Owner's Manual page 11

120/240 volt-4750 watt generator
Hide thumbs Also See for 919.679470:
Table of Contents

Advertisement

Connecting
Generator
To Main
Electricam
Supply
Potenfiai hazards exist when an ebctrbai generator is con-
nected to the main ebctricai suppiy coming into the house.
It is at that point that the generator couid feed back into the
ufiiity company's system causing possibb ebctrocution
of
workers who are repairing ebctrbai
Hines.To avoid back
feeding of ebctrbity
into utiiity systems, a double4hrow
transfer
switch
shouid be installed between the genera-
tor and utility power. This device should be installed by a
licensed electrician and in compliance with all local ebctri-
cal codes.
NOTE: When installing a Doubb-Throw
Transfer Switch,
a minimum of 10 gauge wiring must be used.
BEFORE
STARTBNG
ENGBNE
t
CAUTION:
Always check engine oil level before
every start. Running engine low of oil or out of oil
1
could result in serious damage to the engine.
Adding
Engine
Oim
Your generator has been shipped without
oil in the
engine. Begin by removing the oil dipstick and plug. Start
pouring the oil in slowly.
The engine will hold approximately
26 ounces of oil. To
check the oil, clean and replace the dipstick.
Do not
screw the dip stick in when checking the oil level. Next,
remove the dipstick to check the level. The oil dipstick is
clearly marked with lines that tell you when the engine
has enough oil. Do not fill above this point,
NOTE:
When adding oil to the engine crankcase, use a
high quality detergent oil classified "For Service
SESG,SH" rated SAE 30 weight. Use no special
additives.
Select the oil's viscosity grade according to
your expected operating temperature&
SAE VJscesity
Grades
Low Oil Shutdown
Your Craftsman generator engine is equipped with Low
Oil Shutdown.
Low Oil Shutdown is a safety device
designed to protect your engine from damage in the
event the oil level in the crankcase is low.
If while the engine is running, the oii gets iow, it wiii
automatically shut itself down and wiii not restart until the
oil is added.
If the oil is low before start-up, the genera-
tor wiii not start until oil is added.
NOTE: The Low Oil Shutdown mechanism is very sensi-
tive. You must fill the engine to the full mark on the dipstick
to inactivate this safety device.
GasoJine
Your generator engine is 4 cycle. Use unleaded fuel only.
Never mix oil with gasoline.
CAUTION:
Never fill fuel tank completely. Fill tank to
1/2" below the bottom of the filler neck to provide
space for fuel expansion. Wipe any fuel spillage from
engine and equipment before starting engine.
I WARNING:
Never fiii fuel tank indoors. Never fiii fuel
|
1
tank when engine is running or hot. Do not smoke
1
when filling fuel tank.
Use clean, fresh,
regular
unleaded
gasoline
with a mini-
mum of 85 octane.
Do not mix oil with gasoline.
If unleaded
fuel is not available,
leaded fuel may be used.
To Start
Your Generator
I
CAUTION: Never run engine indoors or in enclosed,
]
poor ventilated areas, engine exhaust contains car-
l
bon monoxide, an ordorbss and deadly gas.
Make sure the fuel shutoff valve is turned to the open
position.
CLOSE
Remove gas cap.
Add unleaded gasoline, slowly, to fuel tank.
Do not overfiiL
o On the engine there is a start/off switch located
on the front panel of the engine. Place this switch to
11 -- ENG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents