2-45 Using the EFI Spectrometer ES-1000
7. In the Get Measurements pane, click Measure.
The Measurement Options dialog box appears.
Page Type is automatically set to the type that
you selected in
8. Check the settings, and click
Measure.
The Information dialog box
appears.
9. Place the ES-1000 in the
calibration cradle, and click
OK.
The EFI Spectrometer
Measurement dialog box
appears. Directions for
measuring the strips appear in
the Status field.
For a more accurate
N
:
OTE
measurement, place several
sheets of plain white paper
beneath the Measurement
Page to block underlying colors from being read by the instrument.
10. Place the sample aperture in the white space at the start of the specified color.
11. Press and hold the measure button and wait for a beep.
To hear a beep with a Windows compatible computer, you must have a sound
N
:
OTE
card and speaker(s) installed.
step
5.
C9800 Color Guide - 45