HP XP1024 System Configuration Manual page 30

Storageworks disk array xp operating system configuration guide: hp-ux
Hide thumbs Also See for XP1024:
Table of Contents

Advertisement

5.
Enter the major numbers for the device drivers into the table. You should now have
all required device and driver information in the table.
6.
Create the device files for all disk array devices (SCSI disk and multiplatform
devices) using the mknod command. Create the block-type device files in the
/dev/dsk directory and the character-type device files in the /dev/rdsk directory.
Example
# cd /dev/dsk
# mknod /dev/dsk/c2t6d0 b 31 0x026000
# cd /dev/rdsk
# mknod /dev/rdsk/c2t6d0 c 188 0x026000 Create character-type file.
:
#
The character-type device file is required for volumes used as raw devices (for
example, 3390-3A/B/C). The block-type device file is not required for volumes
used as raw devices.
If you need to delete a device file, use the rm –i command.
Bus
Inst
Disk
HW path
02
3
8/12
8/12.8.8.255.0.6.0
02
4
8/12
8/12.8.8.255.0.6.1
5
02
8/12
8/12.8.8.255.0.8.0
30
Installation
Driver
Dev
TID
type
OPEN-9
6
sdisk
OPEN-9
6
sdisk
3390-3B
8
sdisk
Go to /dev/dsk directory.
Create block-type file.
File name, b=block-type,
31=major #, 0x026000= minor #
Go to /dev/rdsk directory.
File name, c=character-type,
177=major #, 0x026000=minor #
LUN
Dev file
Minor no.
0
0x026000
c2t6d0
1
0x026100
c2t6d1
0
0x028000
c2t8d0
Major
Major
no.
no.
char.
block
files
files
188
31
188
31
188
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp12000Xp10000Xp128

Table of Contents