Electric Wiring - Sharp GX-X18JR Installation And Operation Manual

Split type room air conditioner
Table of Contents

Advertisement

Available languages

Available languages

Drain vent for repair use (plastic
stopper is included) (drain the water
in waterspout by this outlet vent)
Above 00mm
Pouring water into the
outlet vent terminal

Electric wiring

• Be sure to disconnect all supply circuits in case of wiring work.
• All field supplied parts and materials must conform to local laws and regulations.
• For electric wiring, refer to WIRING DIAGRAM attached to the unit body.
Wiring of the indoor unit.
Remove the control box lid, pull the wires inside through rubber bush A and wiring according to
the WIRING DIAGRAM , then tighten it with clamp.
Wiring of the controller
. Remove the control box lid, pull wires inside through rubber bush B and connect to the
controller.
2. Wrap the wire with sealing pad.
3. After wiring, tighten it with clamp and fix the control box lid.
4. Connect the rubber wire (3-cords) to the power supply terminal board in properly.
Precautions:
Be sure to connect the indoor unit and outdoor unit at right poles.
GX-X8JR
GREE_cassette_eng.indd 25
Drain hose
Pouring water into the test hole
Plastic water pot (The length of the
pipe should be about 00mm.)
GX-X24JR/GX-X36JR
Terminal board
Control box lid (2)
E-25
Test hole cover
Test hole
power supply terminal board
Clamp
Seal here to avoid leakage
Rubber bush A
Clamp
Rubber bush B
Control box lid (2)
08.10.28 11:42:46 AM