Appendix III: RHAON Hardware Inputs, Outputs & Indicators, Dimensions
analog audio to an IC-R array, as well as Fault Detect and Fault Relay lines.
Primary Analog Input/Output
XLR female
pin 1 chassis, pin 2 +, pin 3 -
Looping Analog Output
XLR female
pin 1 chassis, pin 2 +, pin 3 -
Overdrive LED
Flashes red when the Primary Analog
Signal LED
Flickers when an audio signal of at
least -30 dBu is present at the primary
analog audio input.
Input Pad & LED Indicator
On / Off 10 dB pad for Primary
Analog Input; allows input signals of
up to +24 dBu when inserted
Push Button Volume Controls
Also function as a manual Standby/
On control
Mute Button
Turn loudspeaker muting on & Off
Primary & Secondary Ethernet
RJ45 female:
when both inputs are connected, if
Primary fails changeover to Secondary
the connector is active, glows steadily
when data is streaming. Green LEDs
glow when connected but inactive, turn
Orange to indicate a faulty connection.
NOTE: To prevent inadvertent operation the Mute, Volume Up & Volume Down, Input Pad and AES/EBU push buttons need to be pressed
and held down for several seconds before they activate.
36
Power LED
Inputs
Voltage Selector
90/260 V AC
Not on all models
IEC Power Connector
& AC Line Fuse
Thermal LED
Lights to indicate that an over-temperature
Secondary Analog Input
Phoenix connector; pin 1 +, pin 2 -,
pin 3 chassis
AES/EBU Digital Audio Input
Phoenix connector, Pin 3 chassis , Pin 4 +
Fault Detect
Opto-isolated input used to monitor the
presence of an external wiring loop;
absence of a voltage is reported to the
DSP and transmitted to the monitoring
computer over the Ethernet. Operates on
5 to 24 V DC. Pin 5 +, Pin 6 -
Looping Secondary Analog Output
Phoenix connector, Pin 1 +, Pin 2 -,
Pin 3 chassis
Fault Relay
NO / NC relay contacts used to report a
failure to an external monitoring system;
used mainly to trigger a failure indication
on a hard-wired monitoring device; handles
up to 0.5 Amps at 24 V AC or DC. Pin 4
normally open, Pin 5 swing blade, Pin 6
normally closed.
AC Power ON/Off
Not under computer control by RHAON.
a remote computer cannot disconnect the AC power.
To toggle between On and Standby manually, hold
both the Up & Down Volume push buttons down for
approximately 3 seconds.