Assigning Digital and Analog Inputs
The larger right portion of the Properties windows vary with the operating mode. The Connect window is divided into an upper light grey
Internal DSP Connections section and and a darker grey lower CobraNet Routing Assignments section.
and which one will be used for the Priority override circuit. RHAON Empowered loudspeakers have provisions for two CobraNet digital
the radio buttons.
Notice that the Analog 1 input includes a 10 dB pad. In the On position it inserts a 10 dB pad into the Analog 1 input, allowing input signals
as high as +24 dBu. Without the pad, the analog inputs clip at +12 dBu.
The square Signal Present indicators turn green whenever a signal is present.. You can activate any of the analog and CobraNet digital
inputs in the upper group. If you select either of the AES/EBU inputs in the lower group, all Analog and CobraNet inputs are disabled.
to the CobraNet network, except for the AES/EBU inputs. AES/EBU signals are clocked separately from CobraNet and cannot be output to
CobraNet from RHAON.
The lower CobraNet Routing Assignments section is where you select which CobraNet input channel you want to use and set up the output
transmitter.
You can use RHAON without digital audio distribution via CobraNet to Control and Supervise your system, or you can combine digital and
analog signal distribution for redundant signal path and/or life safety applications. However, if you use AES/EBU serial digital inputs,
all other audio inputs are automatically disabled.
If you are not using CobraNet for digital audio distribution in your RHAON system, you can skip the next two pages and move on to Control