Page 1
Installation and service must be performed by an additional information consult an authorized authorized installer or service agency. installer or service agency. Tested by: IMPORTANT: SAVE THESE INSTRUCTIONS GF55-080 06/09/09 FPI FIREPLACE PRODUCTS INTERNATIONAL, LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4...
Page 2
Safety Note: If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection requirements in your area. The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.
TABLE OF CONTENTS * This manual is designed for the technician in conjunction with the owner’s manual. * GFI55 Pellet Insert............15 SAFETY LABEL Clearances to Combustibles........15 Fireplace Specifi cations..........15 Copy of Serial No. Decal ..........4 Pedestal & Leveling Legs ........15 Hopper Cover &...
SAFETY LABEL This is a copy of the label that accom- panies each GF55 & GFI55. We have printed a copy of the contents here for your reference. On the GF55 the safety label is located on the underside of the hopper lid. On the GFI55 the safety label is located on the hopper cover behind the top faceplate.
Unit hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. SINCE FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, FPI GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SOOT: Operation of the stove with insuffi...
INSTALLATION REMOVING PELLET STOVE FROM PALLET To remove your new stove from its pallet, remove the two (2) screws securing the bottom to the pallet. Freestanding: Fireplace Insert: One screw can be easily seen from behind but to access the second screw There is one screw on either side of the bottom.
INSTALLATION GF55 FREESTANDING PELLET STOVE CLEARANCES TO COMBUSTIBLES ALCOVE CLEARANCES These dimensions are minimum clearances to combustibles, however it is highly recommended that you leave suffi cient room on each side (20" where possible) for servicing, routine cleaning and maintenance. Minimum Width 36"...
5. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond the control of FPI, we grant no guarantee against such incidents.
INSTALLATION OUTSIDE FRESH AIR CONNECTION EXHAUST AND FRESH AIR INTAKE LOCATION Outside fresh air is mandatory when installing this unit in airtight EXHAUST: homes and mobile homes. Base of unit to center of fl ue 20-5/16" (508mm) A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as Side of unit to center of fl...
INSTALLATION HORIZONTAL EXHAUST THROUGH WALL INSTALLATION Vent installation: install vent at clearances specifi ed by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a fl oor, or ceiling. Where passage through Exhaust Tube a wall or partition of combustible construction is desired, the installation 3"...
INSTALLATION VERTICAL RISE WITH HORIZONTAL INSIDE VERTICAL INSTALLATIONS TERMINATION INSTALLATION 1. Choose a stove location that is ideal. Refer to "Locating Your Pellet Appliance" section. A 45° elbow may be used in place of the termination cap (or stainless steel termination hood). 2.
INSTALLATION HEARTH MOUNT INSTALLATION OUTSIDE VERTICAL INSTALLATIONS 1. Lock fi replace damper in the open position. To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the "Inside Vertical Installation" section and then fi nish it by performing 2.
INSTALLATION GFI55 PELLET INSERT CLEARANCES TO COMBUSTIBLES INSTALLING HOPPER COVER AND ADJUSTING HOPPER HEIGHT The fi replace insert is certifi ed to be installed into a masonry fi replace only and/or zero clearance wood burning factory built fi replace where allowed The hopper cover initially comes upside-down on top of the hopper.
INSTALLATION EXHAUST AND FRESH AIR INTAKE LOCATION MASONRY FIREPLACE INSERT INSTALLATION The GFI55 requires a surround faceplate and a pedestal. When installing EXHAUST: this unit, ensure that the pedestal is removed from the inside of the hopper Base of unit to center of fl ue 9-1/16"...
INSTALLATION When installing the fi replace insert into a zero clearance fi replace, where When installing the insert into a masonry fi replace DO NOT remove any allowed by local codes, DO NOT cut or modify any factory fi rebox parts. bricks or masonry, with the following exception;...
INSTALLATION INSTALLATION AND REMOVAL OF CONTROL PANEL IN THE SURROUND PANEL When installing the circuit board control panel into the surround panel, the surround does not need to be assembled. The circuit board will be found in the fi rebox. Place the circuit board control panel on the backside of the right surround panel so the hinge is on the outside and the top and bottom holes on the control panel line up with those on the surround.
INSTALLATION PLATED DOOR INSTALLATION THERMOSTAT INSTALLATION TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE 1. Install the thermostat by connecting a low voltage millivolt thermostat to COVER WHEN PELLET STOVE IS HOT! the circuit board jumper location shown below. Connect 2 x 18 gauge wires from the connection points on the back of the control board to the thermostat (see fi...
INSTALLATION SLIDER / DAMPER SET-UP The easiest way to make sure that an effi cient fl ame is achieved is to THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, understand the characteristics of the fi re. IT IS USED TO REGULATE THE AIRFLOW THROUGH THE PELLET STOVE.
TROUBLESHOOTING TROUBLESHOOTING FAQ'S DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualifi ed technicians should deal with possible internal electrical failures. ● Do not attempt to remove or loosen any screws from inside the fi rebox without applying penetrating oil (ie. WD40) to any of the screws. WHAT TO DO IF: 1.
Page 22
TROUBLESHOOTING Blocked exhaust / venting system - Have stove and venting cleaned and inspected. Severe negative pressure in area where unit is installed - Check the operation by opening a window, does this solve the problem? If it does, install fresh air intake to unit or room.
TROUBLESHOOTING WIRING DIAGRAM Combustion Blower Blue 120 °F Brown Exhaust White Vacuum Temperature Switch Brown Sensor Centre Post Grey Un-used 160 °F Purple Convection Temperature Grey Black Switch White White White 120 V Grounded Connector Ignitor Ground Green White Black White Thermostat Yellow...
PARTS LIST PARTS LIST & COMPONENTS Part # Description Part # Description 15) GF55-040 Door Handle GF55/GFI55 1) GF55-001 Auger Motor 115V 1 Rpm GF55-041 Door Handle Bolt, Nut, Washer GF55/GFI55 2) GF55-002 Combustion Blower Motor Only 115V 3) GF55-003 Convection Blower 115V 16) GF55-042 Slider Damper Rod W/Knob GF55/GFI55...
WARRANTY FPI is the manufacturer of the Greenfi re line of heating products. At FPI, our commitment to the highest level of quality and customer service is the most important thing we do. Each Greenfi re stove is built on a tradition of using only the fi nest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser.
9. This warranty does not cover products made or provided by other manufacturers and used in conjunction with the operation of this stove without prior authorization from FPI The use of such products may nullify the Limited Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Greenfi...
Page 30
27. FPI is not liable for freight or labour on any stove replaced in-fi eld and is not liable for travel costs for service work. In the event of in-home repair work, the customer will pay any in-home travel fees or service charges required by the Authorized Dealer.