Motor
This motor has a manual thermal
overload protector. If the motor over-
heats for any reason, the overload
protector will shut off the motor. The
motor must be allowed to cool down
before restarting.
To restart:
1.
Place the On/Auto/Off
lever in
the Off postion.
2.
Allow the motor to cool.
4.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5.
Lift retaining clip from handle and
remove handle.
3.
Depress the red reset button on
the motor.
4.
Place the On/Auto/Off
lever in
the On/Auto postion to restart
the motor.
Pressure
Switch
- Replacement
Pressure loads
beyond
design lim=
its may cause tank rupture or
explosion.
Pressure switch
opera=
tion is related
to motor
HP, tank
rating, and safety valve setting.
Do
not attempt
to adjust, remove,
or
defeat the pressure switch,
or
change
and modify any pressure
control
related device,
if replace=
ment is necessary
the same rated
switch
must be used. Contact
a
trained
service
technician
for
replacement.
To Replace
Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air compressor.
3.
Remove the regulator ring and
remove the console cover.
6.
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
ulator
7.
Remove the outlet pressure
Tank
Pressure
Gauge
8.
9.
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
Remove the regulator.
Apply pipe sealant tape to the
nipple.
21- ENG