Download Print this page

Craftsman 919.195410 Owner's Manual page 16

Oil lubricated single stage horizontal portable air compressor
Hide thumbs Also See for 919.195410:

Advertisement

Available languages

Available languages

6.
After 20 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out"
pressure and
the motor will stop.
The compressor
is now ready for use.
Before
Each Start=Up:
1.
Place On/Auto/Off
lever to
"OFF".
2.
3.
Pull regulator knob out, turn
counterclockwise
until it stops.
Push knob in to lock in place.
Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.
Too much air pres-
--
sure causes a haz-
ardous
risk of bursting.
Check the
manufacturer's
maximum
pressure
rating for air tools and accessories.
The regulator
outlet pressure
must
never exceed the maximum
pres-
sure rating.
How to Start:
1.
Turn the On/Auto/Off
lever to
"AUTO" and allow tank pressure
to build.
Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and
turn clockwise to increase pres-
sure. When the desired pressure
is reached push knob in to lock
in place. The compressor
is
ready for use.
NOTE: Always operate the air com-
pressor in well-ventilated
areas free
of gasoline or other combustible
vapors. If the compressor
is being
used to operate a sprayer DO NOT
place near the spray area.
D24910
16- ENG

Advertisement

loading