Break-In Procedure; Pressure Release Valve; Motor Overload Protector; How To Use Your Unit - Craftsman 919.167320 Owner's Manual

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.167320:
Table of Contents

Advertisement

Available languages

Available languages

Air Compressor
Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor
has raised the air tank
pressure above that required at the
air outlet.
Check Vatve: When the air
compressor
is operating, the check
valve is "open", allowing compressed
air to enter the air tank.
When the
air compressor
reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Motor Overload
Protector:
The
motor has an automatic reset
thermai overioad protector, if the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to coot down before restarting.
The
compressor
will automatically
restart
after the motor cools.
How to Use Your Unit
Now to Stop:
1.
Set the On/Auto/Off
lever to
"Off".
Before
Starting
Break_in Procedure
Pressure
Release Valve:
The
pressure release valve located on
the side of the pressure switch, is
designed to automaticalIy
release
compressed
air from the compressor
head and the outlet tube when the
air compressor
reaches "cut-out"
pressure or is shut off. The pressure
release valve alIows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds.
No air should be heard leaking when
the motor is running or after the unit
reaches "cut-out"
pressure.
damage
may resuBt if the following
break_in instructions
are not
closely
followed.
This procedure is required before the
air compressor
is put into service and
when the check valve or a complete
compressor
pump has been replaced.
1.
Make sure the On/Auto/Off
lever
is in the "Off" position.
NOTE: Pull coupler back until it clicks
to prevent air from escaping through
the quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
InstalIation section of this
manual.)
3.
Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
4.
Move the On/Auto/Off lever
to "On/Auto" position. The
compressor will start.
13-ENG