Zephyr Willow AK8800AG Use And Installation Manual

Hide thumbs Also See for Willow AK8800AG:

Advertisement

Quick Links

ESSENT ALS
www.zephyronline.com
"0
!1 lmmm
Ilow
AK8800AS
AK8800AG
INTENDED
FOR OUTDOOR
COVERED
PATIO OR LANAI AREA.
®
C
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
AUG08.0101 © 2008 Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr Willow AK8800AG

  • Page 1 ESSENT ALS www.zephyronline.com Ilow "0 AK8800AS !1 lmmm AK8800AG INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA. ® Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © 2008 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 ze/:} "/vio lie ,__'_, .v., _i'/"";...
  • Page 3 SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........5 Mounting Height & Clearance ........ 6 Ducting Options ............Specifications ............... Electrical ................. Installing the Power Pack ........10 CONTROLS Rocker Switch Controls ..........11 MAINTENANCE Cleaning and Installing Filters ....... 1 2 Lights ................
  • Page 4 READ AND SAVE THESE INSTRUCTIONS '_','_','_', . :.._-./J y ,..., ..... WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5: Operation

    CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within wails, ceilings, attics, crawl spaces or garages• OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
  • Page 6: Hardware Package Contents

    MODELS: AK8800AS AND AK8800AG PARTS SUPPLIED 1 - 316S High quality stainless steel Power Pack (AK8800AS) 1 - Gray powder coated Power Pack (AK8800AG) 2 - Baffle filters 2 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1 - 8"...
  • Page 7 Duct pieces Equivalent number Duct pieces Equivalent number Total length x used Total length x used 3-1/4"x10" 1 Ft. 6" Round 30 Ft. Rect., wall cap straight with damper 6" Round, 1 Ft. straight roof cap 7"-10" Round, 1 Ft. 6"...
  • Page 8 Minimum mount height between range top to hood bottom should be no less than 30". Maximum mount height should be no higher than 36". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard;...
  • Page 9: Fire Hazard

    WARNING FiRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape. Some Ducting Options i..
  • Page 10 316 High Class Stainless Steel Body for AK8800AS 11 7/16" -4----+-_ _,_o 1/2" 14 11/1 eLi_ 6" 3/16" elec 2" 1 5/16" 2 5/8" 14 11/16" 15 13/16" side 24 5/8" 14 3/4" 1_7 3/4,, 1 6" _3,4,,/ ...._........2 3/8"k.,,,,,,,,J L 25 15/16"...
  • Page 11 ELECTRICAL WARNING All Electrical work must be performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
  • Page 12 CAUTION: At least two installers are required due to the weight and size of the hood. Remove support screw from top of Power Pack AK8800Ax before installing into cabinet. FIG 2b 26 1/16" Place 8" round adapter on top of power pack and secure with (4) M4x8 screws•...
  • Page 13 Lights On/Off ,@+2 Adjust Blower Level (2 Speeds) Light OntOff By pressing 0, the light is switched On and Off_ H is on, 0 is off_ Blower Speed Selection = for level two, The 2 speed levels are selected by switching to - for level one and Switching the rocker switch to middle 0 will turn off the blower,...
  • Page 14: Surface Maintenance

    CAUTION: If this hood is installed in a salt water area (example: coast), rinse all surfaces once a week with clear water (even if the hood is not used), and wipe dry completely. SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scoring pads which wilt scratch and damage surface.
  • Page 15 Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen. mmlm For Zephyr part numbers please turn to page 15 of the manual. Bottom View...
  • Page 16: Ctroubleshooting

    TROUBLESHOOTING PROCEDURES FOR WILLOW ISSUe Cause What to do 1. Make sure the circuit breaker and the unit's After installation, The power source is not turned ON. the unit doesn't power is ON. work. The power line and the cable locking connector 2.
  • Page 17 DESCRiPTiON PART Replacement Parts ZOB-0023 Light Bulb MR16 (GUI0) 35W (each) 50210010 Baffle Filter (each) Optional Accessories Liner, 36" AK0886AS < Liner, 42" AK0882AS Liner, 48" AK0888AS Liner, 54" AK0884AS Liner, 60" AK0880AS To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368 I&,...