Initialization - Epson Photo750 Service Manual

Epson service manual color inkjet printer stylus photo750
Table of Contents

Advertisement

EPSON Stylus Photo 750
† No Ink Cartridge
When the printer detects that ink-cartridge comes off, it becomes
"No ink cartridge error" condition.
„ When you need to perform test print after the repair
service, performing the status-printing(see "Control
Panel" on page -21) provides the discharged ink
condition from the all ink nozzles and the current
value of the waste ink counter. Be sure to check
that the counter value still has enough capacity.(if
the value is closer to 2700 or not)
„ If there is no enough capacity, exchange the waste
ink absorber and find out if it is necessary to reset
EEPROM or not. If you need to reset EEPROM, refer
to "Special Setting Mode" on page -22.
† Maintenance request
When the total quantity of ink wasted with cleaning and flushing
reaches the limit, the printer indicates this error and stops printing.
The absorber in the printer enclosure should be replaced with a new
one by a service person. The counter is added by points and its limit
is as follows.
„ 37000 point = Approx. 418ml
† Fatal Errors
When the printer detects a problem with controlling the mechanical
components or assessing the CG, it becomes "fatal error" condition.
„ Control Error
Defective parallel adjustment, defective HP detection, scarcity of
lubrication on the carriage shaft etc.
„ Logic operation error
Shorted circuit, etc.
Product Description

1.4.7 Initialization

There are 3 types of initialization.
† Power-on Initialization
This printer initializes itself when it is turned on, or when it
recognizes the cold-reset command (remote RS command).
On this initialization, following actions are performed.
„ Initialize mechanical components
„ Clear the input buffer
„ Clear the print buffer
„ Set default values
† Operator initialization
This printer initializes itself when it is turned off and is turned on
again within 10 seconds, or when it recognizes the -INIT
signal(negative pulse) on parallel interface. On this initialization,
following actions are performed.
„ Cap the print head
„ Eject paper
„ Clear the input buffer
„ Clear the print buffer
„ Set default values
† Software initialization
"ESC@" command also initializes the printer. On this initialization,
following actions are performed.
„ Clear the print buffer
„ Set default values
Function