EPSON Stylus Photo 750
„ Since there is a spring inside the pump assembly,
be careful of the spring popping out.
„ When assembling, be careful not to pinch or give
pressure to the ink tube, which is connected
between "Pump, Assembly" and "Cap, Assembly".
„ After installing the "Pump, Assembly", rotate the
"Gear, 67.2" and check if the cleaner part moves
back and forth. (At this time, hold the "Cap,
Assembly" toward the right direction of the frame")
Figure 4-10. Component Parts of "Pump, Assembly"
Disassembly and Assembly
O K
Disassembly
N G
Figure 4-11. Ink Tube
Revision A
62