Status Led; Diagnostic Code - Ultra Start 3250M Installation Manual

Advanced 2-way remote vehicle starter
Hide thumbs Also See for 3250M:
Table of Contents

Advertisement

3250 Wiring Diagram
Pre-Installation
Components
Pre Installation Check
Installation Procedure
Wire Connectors
6 Pin Connector
14 Pin Connector
4 Pin Red Connector
2 Pin White Connector
Jumper Selection
Installation
Basic Installation - Quick start
Auto Tach Learn
Programming
Program Overview & System Reset
Program Menu 1 (User Settings)
Program Menu 3 (Starter Settings)
Program Menu 4 (Tach Settings)
Operations
Transmitter Operation
Timer Mode Settings
Reservation Mode ( Manual Transmission Only)
Additional Operations
Transmitter Programming
Service Mode (Valet Mode)
Relay Diagrams
DIAGNOSTICS
PARK LIGHTS
3 Flashes
3 Slow Flashes
4 Slow Flashes
4 Flashes
6 Flashes
7 Flashes
8 Flashes
If the remote starter has a failed start attempt or if a safety input is activated the Diagnostic Memory will store
up to four shutdowns in memory. This information can then be accessed to determine the source of the
shutdown.
To Enter Diagnostic Mode:
Step 1 - Turn the ignition on wait two seconds then turn off. Press the Program Button and release.
Step 2 - The system will respond with three park light flashes and the horn will honk (optional) the
same number of times as the events in memory. ( Maximum four events, four honks)
NOTE: If the horn does not honk, there are no events in memory.
Step 3 - Press the Program Button once to view the last shut down code. The (optional) Horn will honk once
to confirm code one. (If the horn does not honk, there are no codes in memory).
Step 4 - The LED's on the antenna will flash a code corresponding to a shut down trigger. Press the
Program Button again to check the second code. The horn will honk twice to confirm code two.
Step 5 - To Clear Diagnostic Memory. While in Diagnostic Mode press and hold the Program Button for five
seconds. The park lights will flash and the horn(optional) will honk once.
NOTE: Once diagnostic memory has 4 shutdown events in memory, the system will not record
2
Any further shutdown events until the system memory has been cleared.

STATUS LED

Series of 3 Flashes
No Flashes
Series of 4 Flashes
Series of 4 Flashes
Series of 6 Flashes
Series of 7 Flashes
Series of 8 Flashes
Page 3
Page 4
Page 5
Page 6
Page 10
Page 11
Page 12

DIAGNOSTIC CODE

Door Opened "M" Models
Start Attempt In Service Mode
Not in Reservation Mode "M" units
Hood Pin Grounded (Open)
Brake Pedal Shutdown
Tach Lock-Out
3 Start Attempts with no start
Page 7-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

3250

Table of Contents