Wiring Diagrams - Goodman GPH 13 M Series Technical Manual

Gph 13 m series multi position package heat pump units with r410a
Table of Contents

Advertisement

WIRING DIAGRAMS

LPS
YL/PK
YL/PK
YL
BL
YL
BK
PU
RD
BL
PU
FC
L1
CHS
C
2 POLE ONLY
SEE NOTE 7
SEE NOTE 5
M1
EBTDR
M2
RVC
R
4
P
L
5
F
6
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
BK
RD
GR
G
EBTDR
BK
NO
R
K1
XFMR-R
COM
BL
K1
C
NC
SPEED
M1
M2
BL
UP
PU
Y
Y
C C
C
OR
C-RV
CNT
PU
DC
R-PS1
RD
O
PS2
BK
O-RV
BK
CCR
LVDR
WH
W
RD
R
R
YL
HVDR
R-DFT
DF2
DF1
DFT
SA
PU
RD
RD
BK
PU
RD
BK
EM
BR
DFT
3 SPEED
BK
RVC
SUPPLY VOLTAGE
208-240/1/60
SEE NOTE 3
CH
T2
C
R
T1
C
COMP
C
HVDR
S
H
RCCF
F
S.A.
CM
BR
P
3
L
F
1
1
3
2
4
SEE
EBTDR
NOTE 2
COM
NC
EM
FC
208-240
SEE NOTE 4
2
1
3
TR
24V
EBTDR
R
C
G
DFT
O-RV
C-RV
R-DFT
R
DC
O
W
Y
R-PS1
PS2
LPS
HPS
R
W2
O
W1
Y
G
C
THERMOSTAT
PU
SEE NOTE 4
BK
1
PU
2
3
C
208
240
RD
BL
24V
1
3
BL
2
RD
RD
PU
4
BR
BK
OR
BK
PU
YL
BR
PU
WH
PLF
3
6
9
H
C
F
2
5
8
BR
RD
RCCF
1
4
7
RD
BR
BL
SEE NOTE #5
PU
(TRANS240V)
(M1) RD
LOW
PU
BR
(COM) BK
HIGH
EM
BR
BR
2 SPEED
CM
OPTIONAL
FC
L2
COMPONENT LEGEND
BR
BLOWER INTERLOCK RELAY
C
CONTACTOR
CCR
COMPRESSOR CONTACTOR RELAY
CH
CRANKCASE HEATER
CHS
CRANKCASE HEATER SWITCH
CM
CONDENSER MOTOR
COMP
COMPRESSOR
DC
DEFROST CONTROL
DFT
DEFROST THERMOSTAT
EBTDR
ELECTRONIC BLOWER TIME DELAY RELAY
EM
EVAPORATOR MOTOR
FC
FAN CAPACITOR
GND
EQUIPMENT GROUND
HPS
HIGH PRESSURE SWITCH
HVDR
HIGH VOLTAGE DEFROST RELAY
LPS
LOW PRESSURE SWITCH
LVDR
LOW VOLTAGE DEFROST RELAY
LVJB
LOW VOLTAGE JUNCTION BOX
PLF
FEMALE PLUG / CONNECTOR
RVC
REVERSING VALVE COIL
RCCF
RUN CAPACITOR FOR
COMPRESSOR AND FAN
SA
START ASSIST
TR
TRANSFORMER
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONL Y.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
"COM" WITH LEAD ON EBTDR "M1" OR "M2".
3. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
DFT
4. FOR 208 VOLT TRANSFORMER OPERA TION MOVE PURPLE WIRES
C
FROM TERMINAL 3 TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.
CNT
6. USE COPPER CONDUCTORS ONL Y ++ USE N.E.C. CLASS 2 WIRE.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR
CONNECTED TO ANY OTHER COMMON (24V).
C
GPH13[24-42]M41AB
SEE NOTE #8
PU
BL
PU
BK
RD
T2
L2
RD
SEE NOTE
C
#6
BK
T1
L1
BK
PU
RD
BK
GND
RD
PU
YL
BL/PK
YL
RD
GR
WH
OR
BR
BL
BK
PU
SEE NOTE #3
RD
BK
YL
BK
S
C R
RD
RD
COMP
CHS
SEE NOTE #3
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
208-240/1/60 0140G01745-A
SEE NOTE #7
2
0
8
-
2
4
0
/
1
/
6
0
BL/PK
LVJB
HPS
T
H
Y
E
R
R
G
M
W1
O
O
S
W2
T
C
A
T
++
CONTROL
BOX
CH
BK
GR
BK
BK
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK
BLACK
BL
BLUE
BR
BROWN
GR
GREEN
OR
ORANGE
PU
PURPLE
RD
RED
WH WHITE
YL YELLOW
27