Goodman GPC1336M41 Installation Instructions Manual

Air conditioners and heat pump units gpc/gph 13 seer m series with r-410a

Advertisement

A
C
IR
GPC/GPH 13 SEER "M" SERIES
Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During
It is your responsibility to install the product safely and to educate the customer on its safe use.
These installation instructions cover the outdoor
installation of self contained package air conditioners
and heating units. See the Specification Sheets
applicable to your model for information regarding
accessories.
IO-395B
9/2011
I
NSTALLATION
F
S
-C
OR
ELF
ONDITIONERS AND
W
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL
installation or repair, caution is to be observed.
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com
© 2010-2011 Goodman Manufacturing Company, L.P.
is a registered trademark of Maytag Corporation or its related companies and is used under
license to Goodman Company, L.P., Houston, TX. All rights reserved.
I
NSTRUCTIONS
ONTAINED
H
EAT
R-410A
ITH
*NOTE: Please contact your distributor or our
website for the applicable Specification Sheets
www.amana-hac.com
P
ACKAGE
P
U
UMP
NITS
C
referred to in this manual.
®
US

Advertisement

Table of Contents
loading

Summary of Contents for Goodman GPC1336M41

  • Page 1 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com www.amana-hac.com © 2010-2011 Goodman Manufacturing Company, L.P. IO-395B 9/2011 is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
  • Page 2: Table Of Contents

    IELD ESTING ROUBLE HOOTING Complete warranty details available from your local dealer or, for ....10 IRFLOW EASUREMENT AND DJUSTMENT ® Goodman brand products, visit www.goodmanmfg.com, and for PEED DJUSTMENTS ® Amana brand products, visit www.amana-hac.com......12 NDOOR LOWER OTOR ......
  • Page 3: Shipping Inspection

    IMPORTANT: To register your Goodman ® brand unit, go to WARNING www.goodmanmfg.com and click “Warranty Registration”. Com- plete registration as prompted. O NOT CONNECT TO OR USE ANY DEVICE THAT IS NOT DESIGN-CERTIFIED ® To register your Amana brand unit, go to www.amana-hac.com OODMAN FOR USE WITH THIS UNIT.
  • Page 4: Epa Regulations

    contained packaged units so the only connections needed for Close to the wall application assures free, unobstructed air to the installation are the supply and return ducts, the line and low other two sides. In more confined application spaces, such as voltage wiring and drain connection.
  • Page 5: Roof Curb Installations

    Horizontal Air Flow (Applies to 3 phase models) Single phase models are shipped without horizontal duct covers. If needed, these kits may be ordered through Goodman’s Service Parts department.
  • Page 6: Duct Work

    ILTERS CAUTION O PREVENT PROPERTY DAMAGE DUE TO FIRE AND LOSS OF EQUIPMENT EFFICIENCY OR EQUIPMENT DAMAGE DUE TO DUST AND LINT BUILD UP ON INTERNAL PARTS, NEVER OPERATE UNIT WITHOUT AN AIR FILTER INSTALLED IN THE RETURN AIR SYSTEM. Filters are not provided with unit and must be supplied and exter- nally installed in the return duct system by the installer.
  • Page 7: Wiring

    WIRING NOTE: All wiring should be made in accordance with the National Electrical Code. Consult your local Power Company to determine the availability of sufficient power to operate the unit. Check the voltage, frequency, and phase at the power supply to ensure it corresponds to the unit’s RATED VOLTAGE REQUIREMENT.
  • Page 8: Startup, Adjustments, And Checks

    3. Slowly raise the heating temperature setting. When the BRANCH CIRCUIT AMPACITY 15 20 25 30 35 40 45 50 heating first stage makes contact, stop raising the SUPPLY WIRE LENGTH - temperature setting.. The compressor, blower and fan FEET should now be running with the reversing valve in the de- energized (heating) position.
  • Page 9: Condenser Motor

    crankcase thereby preventing liquid migration and subsequent EATING YCLE compressor damage. The insert type heater is self regulating. It is The heat pump operates in the heating cycle by redirecting refrig- connected electrically to the contactor L1 and L2 terminals. erant flow through the refrigerant circuit external to the compres- Condenser Motor sor.
  • Page 10: Defrost Control

    supplementary heat for all heat pump installations in areas where 8. The control is shipped from the factory with the compressor the temperature drops below 45° F. It is also a good practice to delay option selected. This will de-energize the provide sufficient supplementary heat to handle the entire heating compressor contactor for 30 seconds on defrost initiation requirement should there be a component failure of the heat pump,...
  • Page 11 E.S.P (In. of H Model Speed Volts 1122 1078 1032 WATTS 1387 1331 1264 1209 1119 1041 WATTS 1521 1454 1388 1311 1230 1144 1055 HIGH WATTS 1,140 1,395 1,360 1,310 1,265 1,235 1,190 1,130 T1 (G) WATTS 1,795 1,765 1,715 1,695 1,650...
  • Page 12: Refrigerant Chargec

    PEED DJUSTMENTS NDOOR LOWER OTOR SATURATED LIQUID PRESSURE PSC Motor TEMPERATURE CHART Adjust the CFM by changing the speed tap of the indoor blower Liquid Saturated Liquid motor at the EBTDR “COM” connection with one of the speed taps Pressure Temperature °F on “M1”...
  • Page 13: Maintenance

    ( F) ( F) and sufficient air volume must pass through the indoor coil to GPH1330M41** ( F) ( F) prevent excessive discharge pressure, and high pressure cut out. GPH/GPC1336M41** (F ) (F ) GPH1342M41** (F ) (F ) UTSIDE...
  • Page 14: Troubleshooting Chart

    TROUBLESHOOTING CHART POSSIBLE CAUSE REMEDY SYMPTOM High head - low suction a. Restriction in liquid line or flowrator a. Remove or replace with proper size flowrator. High head - high or normal suction a. Dirty condenser coil a. Clean coil. b.
  • Page 15: Appendix

    APPENDIX UNIT DIMENSIONS POWER WIRE ENTRANCE 4 1/8 2 1/8 1 3/8 5 ½ 6 ½ 2 34 RETURN SUCTION/LIQUID PRESSURE PORT SUPPLY CONDENSATE DRAIN CONTROL 18 7/8 CONNECTION WIRE 3/4” NPT FEMALE ENTRANCE BLOWER ACCESS PANEL MEDIUM CHASSIS GP*1324M4** GP*1330M4** GP*1336M4** GP*1342M4**...
  • Page 16: Minimum Clearances

    3-1/2 ton 4 ton 5 ton Min. Filter Size (1) 25x25x1 (1) 25x25x1 (1) 25x25x1 (1) 25x25x1 (2) 20x20x1 (2) 20x20x1 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com www.amana-hac.com © 2010-2011 Goodman Manufacturing Company, L.P.

Table of Contents