Operation flow and applicable data, etc.
12. Air
This function generates nagative ion while cleaning the
purifying
air in the room.
control
If air purifier-ON signal is received while the air condi-
tioner stops, the air purifier starts operation, and if it is
received while the air conditioner operates, the air
conditioner and the air purifier start operation.
The air ion generator operates linked with the air
purifying operation.
Air conditioner stops
OPERATION indicator ON
Memory position
of louver/COOL
Air purifier ON
Air purifying operation
Air purifier operates
OPERATION indicator OFF
Air purifier-OFF
Sending air purifier-ON
,
1
2
1
Air conditioner operates
Start of air purifier-ON
*1
*2
Fan ON
Sending air purifier-OFF
,
3
4
3
Fan stop
Air conditioner operates
Louver close
All stop
2
Air conditioner +
air purifier operate
4
Air conditioner +
Air purifier operate
Filter-OFF
– 49 –
Description
Operation button
Present
PURE button
status
Stop
Air purifier
Air purifier only
Stop (All)
Air conditioner
AC + Air purifier
Joint use of AC
AC operation
and air purifier
* When the previous operation was the
operation of air conditioner + air purifier,
an operation of air conditioner + air
purifier starts by pushing AC button on
the remote controller.
(Operation of air conditioner + air
purifier is stored in memory.)
Louver*1
Air purifying
Cooling position
operation
Follows to
AC + Air purifying
AC operation
operation
*1 Swing is available
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) → (L) → (L–) → (SL).
Air conditioner
AC operation*
AC + Air purifier
All stop
All stop
Fan speed *2
AUTO, L, L+, M,
M+, H
Follows to
AC operation