Temporary Operation; Air Purifying Control - Toshiba RAS-B10SKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-B10SKVP-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
11. Temporary
Pressing [RESET] button starts the temporary
operation
operation of [AUTO] operation. When keeping [RE-
SET] button pressed for 10 seconds or more, the
temporary [COOL] operation is performed.
Filter lamp ON
NO
Did you press [RESET] button
for 3 to 9 seconds?
YES
Did you press [RESET] button
for 10 seconds or more?
NO
Switch to [AUTO RESTART] control.
12. Air purifying
This function generates nagative ion while cleaning the air in the room.
control
If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation, and
if it is received while the air conditioner operates, the air conditioner and the air purifier start
operation.
The air ion generator operates linked with the air purifying operation.
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Air purifying operation
AC + Air purifying operation
Sending air purifier-ON
1
Air conditioner stops
Operation lamp ON
*1
Memory position
of louver/COOL
*2
Fan ON
Air purifier ON
Air purifying operation
YES
Press RESET button.
NO
Temporary [AUTO] operation
YES
Temporary [COOL] Operation
Operation button
PURE button
Air purifier
Stop (All)
AC + Air purifier
AC operation
Louver*1
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
Follows to AC operation
1
,
2
2
Air conditioner operates
Start of air purifier-ON
Air conditioner +
air purifier operate
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, "Pi" sound is
heard and the temporary [COOL] opera-
tion starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then,
to stop the temporary operation, press
[RESET] button again.
* When the previous operation was the
operation of air conditioner + air purifier,
Air conditioner
an operation of air conditioner + air purifier
AC operation*
starts by pushing AC button on the remote
controller.
AC + Air purifier
(Operation of air conditioner + air purifier is
All stop
stored in memory.)
All stop
*1 Swing is available
Fan speed *2
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) → (L) → (L–) → (SL).
Sending air purifier-OFF
3
Air purifier operates
Operation lamp OFF
Fan stop
Air purifier-OFF
Louver close
All stop
– 45 –
Description
,
3
4
4
Air conditioner +
Air purifier operate
Filter-OFF
Air conditioner operates

Hide quick links: