SPECIFICATIONS
•
Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
•
Power consumption is measured when the fan runs at the highest speed setting.
•
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Power Supply (Ph/V/Hz)
Rated Cooling Capacity (BTU/h)
Cooling Power Input (Watts)
Rated Current Cooling (Amperage)
EER/C.O.P
Noise Level dB(A) (H/M/L)
CFM (H/M/L)
Dehumidifying Capacity
Product Dimensions (W" x H" x D")
Package Dimensions (W" x H" x D")
Net/Gross Weight (Lbs)
Refrigerant Type
Plug Type
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFI-
CATIONS PRESENTED IN THIS USER'S MANUAL
ARE THE PRESENTATION OF THE MANUFAC-
TURER. SOLEUS INTERNATIONAL HAS NOT CON-
DUCTED INDEPENDENT TEST TO THE INFORMA-
TION AND THE SPECIFICATIONS PRESENTED
HEREWITHIN.
Model
GM-WAC-15ESE-C
1/115/60
15,000
1400
12
10.7
58/56/54
470/430/390
100 Pints per day
23.625 x 17.75 x 25.5
28.25 x 20 x 26.125
108/120
R-410A
NEMA 5-15P
GM-WAC-18ESE-C
1/230~208/60
18,000/17,600
1,680/1,650
8.1/8.8
10.7/10.7
58/56/54
470/430/390
132 Pints per day
23.625 x 17.75 x 25.5
28.25 x 20 x 26.125
113/125
R-410A
NEMA 6-15P
5