Hitachi PJ TX100 - LCD Projector - HD 720p Owner's Manual page 38

Owners guide
Table of Contents

Advertisement

Troubleshooting
Regarding the indicator lamps (continued)
POWER
LAMP
indicator
indicator
Blinking
In
Red
Turned
or
off
Lighting
In
Red
Blinking
In
Red
Turned
or
off
Lighting
In
Red
Lighting
Alternative
blinking in
In
Green
Lighting
Simultaneous
blinking in
In
Green
38
TEMP
indicator
The cooling fan is not operating.
Please turn the power off, and allow the unit to cool
down at least 20 minutes. After the projector has
Blinking
suffi ciently cooled down, please make confi rmation
In
Red
that no foreign matter has become caught in the fan,
etc., and then turn the power on again.
If the same indication is displayed after the treatment,
please contact your dealer or service company.
There is a possibility that the interior portion
has become heated.
Please turn the power off, and allow the unit to cool
down at least 20 minutes. After the projector has
suffi ciently cooled down, please make confi rmation of
Lighting
the following items, and then turn the power on again.
In
Red
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment,
please change the lamp by referring to the section
"Lamp".
There is a possibility that the interior portion
has become overcooled.
Please use the unit within the usage temperature
Red
parameters (5°C to 35°C). After the treatment, resent
the power to ON.
It is time to clean the air fi lter, or there is no air
fi lter.
Please immediately turn the power OFF, and clean
or change the air fi lter by referring to the section "Air
Red
Filter". After cleaning or changed the lamp, please be
sure to reset the fi lter timer. After the treatment, resent
the power to ON.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pj-tx100