11-3 AC VOLTAGE IS NORMAL AT NO-LOAD, BUT
THE
LOAD CANNOT
BE
APPLIED.
11-3-1 CHECK THE ENGINE SPEED.
I f the engine speed is low, adjust it to the rated r.p.m.
*Refer to Step 11 -2-1 for engine speed adjustment.
11-3-2 CHECK THE TOTAL WAnAGE OF APPLIANCES CONNECTED TO THE GENERATOR.
Refer to Section
7
"RANGE OF APPLICATIONS" for the wattage of the appliances.
If the generator is overloaded, reduce the load to the rated output of the generator.
11-3-3 CHECK THE APPLIANCE FOR TROUBLE.
If the appliance is faulty, repair it.
11-3-4 CHECK IF THE
ENGINE
IS OVERHEATED.
-
If the cooling air inlet and/or cooling air outlet
i s
clogged with dirt, grass, chaff or other debris, re-
move it.
(ALTERNATOR)
Fig.
11-6
11-3-5 CHECK THE INSULATION OF THE GENERATOR.
(1)
Stop the engine. Remove the control panel;
and disconnect the connector of GREEN lead
for ground.
(2) Measure the insulation resistance between the
live terminal
o f
the receptacle and the ground
terminal.
If the insulation resistance is less than
1
M
Q
,
disassemble the generator and check the in-
sulation resistance of the stator, rotor and the
live parts in the control box. (Refer to Section
Any part where the insulation resistance
is less
than 1 M
SZ
,
the insulation is faulty and may
cause electric leakage.
Replace the
faulty
part
8-3.)
-