5-2-9 GFCI RECEPTACLE
After starting the engine, check the GFCI for'proper functioning by the following test procedure.
Push blue TEST button, The red RESET button will pop out exposing the word TRIP. Power
is now
off
at
the outlets protected by the GFCI, indicating that the device is functioning properly.
If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician.
To restore power, push RESET button.
WARNING :
If the RESET button pops out during operation, stop the generator immediately and
call a
qualified electrician for checking generator and the appliances.
5-2-10 CONNECTING TO DOMESTIC CIRCUITS
(HOUSE
WIRING)
Fig.
5-9
WARNING :
This generator
i s
a neutral grounded
type.
ff
a generator is to be connected to residential or commercial
power lines, such as a stand-by
Faitwe
in
connection may result in death, personal injury, damage to generator, damage to appli-
ances, damage to the building's wiring or fire.
(a) When contnecting a Robin generator to a house wiring, generator output power must
be taken from
.
power source during power outage,
all
connections must be made by a licensed electrician.
the
240V-4P
receptacle.
-
11
-