Robin America RGV7500 Service Manual page 12

Table of Contents

Advertisement

5-2-5
IDLE
CONTROL
UNIT
The idle control unit releases throttle valve when
the applied load current exceeds 0'.04A.
The two output wires from the main coils must go
through the ZCT in the same direction.
NOTE :
It is normal that the engine speed goes up for a
moment when you turn the key switch
to "STOP"
while the Auto Idle Switch
is
in "ON" position.
I
Fig.
5-6
5-2-6 NO-FUSE BREAKER
The no-fuse breaker protects the generator from getting damage by overloading
o r
short circuit in the
appliance. Table 5-1 shows the capacity of no-fuse breaker by each spec. and their object of protection.
I
SPECIFICATION
OBJECT
of
PROTECTION
NO-FUSE BREAKER
60 HZ- 120
V/
240V
'
Total
output
amperage
25 A (2-Pole, 2-Element)
Table.
5-1
5-2-7 DC CIRCUIT BREAKER
The
10
ampere
DC
circuit breaker mounted on
the control panel protects whole DC circuit from
getting damage by overload or short circuit.
Fig. 5-7
-
9 -