The jumpers
Jumpers at J2 are single position jumpers; they can be either
installed or disconnected. To change the settigs of these jumpers you
must put a jumper plug across the two pins. To disconnect a jumper plug,
simply move the plug so that it
right pin open. (All plugs are in this position when the interface is
delivered from the factory.)
Table. Function so the jumpers
T2
Connects DM+ and DM- through a 120 ohm resistor.
Tl
Connects RD+ and RD- through
Connects RD- to pin 9
E L
Connects RD+topin 10
D M
Connects DM- to pin 23
DM+
Connects DM+ to pin 24
SD+
Connects SD+topin 12
TR+
Connects TR+ to pin 25
TR-
Connects TR-to pin 13

Communications Protocols

To achieve the maxim um printing speed, the computer should send
characters to the printer faster than the printer can print them. This
ensures that the printer has to stop and wait for more
information. But if you continuously send information to the printer
faster than it can print, sooner or later the printer's buffer will
overflow and information will be lost. A communications protocol keeps
the computer from sending more information than the printer can
handle.
The GQ-35CN7's serial interface can use three different kinds of
communications protocols These are described in detail below.
The ETX/ACK protocol
The ETX/ACK protocol uses a special pair of control codes, ETX
(ASCII 3) and ACK (ASCII 6). The system is very simple: whenever
the GQ-3500 gets an ETX out of its input buffer it sends an ACK back to
the computer. When the computer receives the
to send more information to the printer without fear of overflowing the
buffer.
8
at J2
*
on the left pin only, leaving the
rests
a
120 ohm resistor.
ACK it knows it is safe