PLC-XL51 Basic Serial Command Specifications

7. Status Read Command

7.1. Format

7.1.1.
PC issues commands in format as below;
"CR" Command [CR]
Commandÿ 1 characterÿ See Basic Status Read Command Tableÿ
7.1.2.
When a projector receives the appropriate command, it returns a character line as the
required data.
Required Data [CR]
Required Dataÿ A character lineÿ See Basic Status Read Command Tableÿ
7.1.3.
When the received data cannot be decoded, the projector returns "?" [CR].

7.2. Transfer Example

Get input mode for projector with basic commands
PC → Projector
Projector → PC
7.3. Status Read Command
Command
"CR0" [CR]
Detail
Get the projector's operating status
Acceptable
Response
Unacceptable
Commandÿ issues a command of getting current input modeÿ
"C" "R" "1" "CR"
"%1" [CR]
"00" = Power ON
"80" = Standby
"40" = Countdown in process
"20" = Cooling Down in process
"10" = Power Failure
"28" = Cooling Down in process due to Temperature Anomaly
%1
"88" = Coming back after Temperature Anomaly
"24" = Power Save/Cooling Down in process
"04" = Power Save
"21" = Cooling Down is in process after Power off due to lamp
failure
"81" = Standby after Cooling Down due to lamp failure