Fujitsu MAP3147 Scsi Logical Interface Specifications page 109

Scsi logical interface specifications 3.5 inch hard disk drives with internal scsi controller
Table of Contents

Advertisement

(1)
Paramter code
This field identifies the log paramter being transferred for that log page.
(2)
Byte 2
a) DU (Disable Update)
"1" :
The IDD does not update the log parameter value except in responce to a LOG SELECT
command that specifies a new value for the parameter.
"0" :
The IDD updates the log parameter value to reflect all events that are noted by that
parameter.
b) DS (Disable Save)
"1" :
The IDD does not support saving that log parameter in response to LOG SELECT or
LOG SENSE command with an "SP" bit of one.
"0" : The IDD supports saving for that log paramter. The IDD saves the current parameter value
in response to LOG SELECT or LOG SENSE command with a "SP" bit of one.
c) TSD (Target Save Disable)
The IDD does not support this bit. For LOG SENSE command (See 3.1.17), the IDD always
report zero. Also, for this command, the IDD accepts this bit value of "1", but ignores its
functionality.
d) ETC (Enable Threshold Comparison)
The IDD does not support this bit. For LOG SENSE command (See 3.1.17), the IDD always
report zero. Also, for this command, the IDD accepts this bit value of "1", but ignores its
functionality.
e) TMC (Threshold Met Criteria)
This field is ignored when "ETC" bit is 0. For LOG SELECT command (See 3.1.17), the IDD
accepts this field value of other than "00b", but ignores its functionality.
f) LBIN
This bit is only valid if the "LP" bit is one. If the "LP" bit is one and this bit is zero then the list
parameter is a string of ASCII graphic codes.
If the "LP" bit is one and this bit is one then the list parameter is a list of binary information.
g) LP (List Parameter)
"1" :
The parameter is a data counter.
"0" :
The parameter is a list parameter.
If these bits are specified by LOG SELECT command, the IDD terminates normally.
But the IDD's action is not changed.
For LOG SENSE command, these bits always report value defined in each log page (see 4.2).
(3)
Parameter length
This field specifies the length in bytes of the following parameter value. If the application client
sends a parameter length value that results in the truncation of the parameter value, the device server
terminates the command with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid
field in parameter list [=26-00]).
C141-E167
3.1 Control/Sense Commands
47
3 -

Advertisement

Table of Contents
loading