NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cieaned, then
reinstalled.
8.
Protect the electrical cord and
9.
air hose from damage (such
as being stepped on or run
over). Wind them loosely around
the compressor
handle. (if so
equipped)
Store the air compressor
in a
clean and dry location.
Risk of Unsafe Operation,
Unit cycles automatically
when
power is on, When servicing,
you may be exposed
to
vomtage sources,
compressed
air, or moving parts, Before servicing
unit
unplug or disconnect
emectricamsuppmy to the air compressor,
bleed tank of
pressure,
and allow the air compressor
to coom,
PROBLEM
CORRECTION
Excessive
tank
pressure
- safety
valve pops
off.
Air leaks at
fittings.
Air leaks in air
tank or at air
tank welds.
Air leaks
between
head
and valve plate,
Air leak from
safety
valve.
CAUSE
Pressure switch does
not shut off motor when
compressor
reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Defective air tank.
Leaking seal.
Possible defect in safety
valve.
Possible defect in safety
valve.
Knocking Noise.
Move On/Auto/Off
lever
to the "OFF" position,
if
the outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. Do Not
Overti
hten.
Air tank must be replaced.
Do not repair the leak.
Risk of
Bursting,
Be not drill into, weld or
otherwise
modify air tank
or it will weaken,
The tank
can rupture
or expmode,
Contact a Trained Service
Technician.
Operate safety valve
manually by pulling on ring.
if valve still leaks, it should
be replaced.
Operate safety valve
manually by pulling on ring.
if valve still leaks, it should
be replaced.
19= ENG