Permanently lubricated tank mounted air compressor

Advertisement

Available languages

Available languages

To Replace
Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2,
3,
Unplug unit.
Using an adjustable wrench or
specified wrench remove the
gauges (7/16" wrench), quick
connect (!3/16" wrench), and
safety valve (9/16" wrench) from
the regulator manifold.
Remove the hose by removing
the hose clamp. NOTE: The hose
clamp is not reusable. You must
purchase a new hose damp, see
the Parts List Manual or purchase
a standard hose clamp at a local
hardware store.
5,
Hose CRamp
Using an adjustable wrench or
5/8" wrench remove the regulator
manifold.
6.
Apply pipe sealant to new
regulator manifold and assemble,
tighten with wrench.
7.
Reapply pipe seaJant to gauges,
quick connect, and safety valve.
8.
Reassemble all components
in
reverse order of removal. Make
sure to orient gauges to read
correctly and use wrenches to
tighten all components.
Before you store the air compressor,
make sure you do the following:
1.
Review the Maintenance section
on the preceding pages and
perform scheduled
maintenance
as necessary.
2.
Set the On/Auto/Off
lever to
"OFF" and unplug unit.
3.
Turn the regulator
counterclockwise
and set the
outlet pressure to zero.
4.
Remove the air tool or accessory.
5.
Pull ring on safety valve allowing
6,
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
Drain water from air tank by
opening drain valve on bottom of
tank.
condense
in the air tank,
if not
drained,
water will corrode
and
weaken
the air tank causing
a risk
of air tank rupture,
7.
After the water has been drained,
close the drain or drain valve.