FMI V)S36 Series Owners Manual And Installation Manual

Residential and outdoor wood burning fireplace

Advertisement

Residential and OutdOOR
WOOd buRning FiReplace
OWneR's OpeRatiOn and
installatiOn Manual
PFS
®
C
US
ICC-ES #ESR-2542
MOdels (V)s36 seRies
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
This fireplace is approved for use as a wood burning fire-
place or for use with a vented gas log approved to ANS
Z21.60 or Z21.84 standards or for use with a vent-free
gas log heater approved to ANS Z21.11.2 standard. A FMI
PRODUCTS, LLC hood must be installed when using a
vent-free log heater (see Accessories, page 16).
This wood burning fireplace complies with UL127-
CAN/ULS-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, fire department,
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V)S36 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMI V)S36 Series

  • Page 1 ANS Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A FMI PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Accessories, page 16).
  • Page 2: Table Of Contents

    Before beginning installation of this fireplace, • Do not place clothing or other read these instructions through completely. flammable materials on or near • This FMI PRODUCTS, LLC fireplace and its components are safe when installed the appliance. according to this installation manual.
  • Page 3: Specifications

    speciFicatiOns ELECTRICAL 1" AIRSPACE OUTLET TO COMBUSTIBLE RIGHT SIDE GAS LINE 0" TO MATERIAL KNOCK OUTS TOP SPACERS NO COMBUSTIBLE MATERIAL ON FACE 8.125" 2.5" 7.092" 8.717" 11.217" AIR KIT KNOCK OUT LEFT SIDE GAS LINE COMBUSTIBLE KNOCK OUTS WALL BOARD 3/4"...
  • Page 4: Fireplace Installation

    FiReplace installatiOn SELECTING LOCATION FRAMING To determine the safest and most efficient 1. Frame opening for fireplace using the location for the fireplace, you must take into dimensions shown in Figures 1 and 2. consideration the following guidelines: 2. If fireplace is to be installed directly on 1.
  • Page 5: Fireplace Installation

    FiReplace installatiOn WARNING: Hearth extension Continued is to be installed only as shown DRAIN PAN (DP36) in Figure 3. For outdoor installations, the fireplace enclo- sure must allow for adequate drainage and MANTELS fresh air ventilation. It is recommended that A mantel may be installed if desired (see a sealed, corrosion resistant catch pan with Figure 4).
  • Page 6: Venting Installation

    Figure 5 - Outside Air Kit 8" Stainless Inner Pipe CHIMNEY PIPE The FMI PRODUCTS, LLC chimney system consists of 12", 18", 24", 36" and 48" snap- lock, double-wall pipe segments, planned Figure 6 - Lineal Gain for maximum adaptability to individual site requirements.
  • Page 7 Venting installatiOn Continued When connecting chimney directly to the fireplace, OFFSET RISE CHIMNEY LENGTH the inner flue pipe section must be installed first 48" 36" 24" 18" 12" with the lanced side up. The outer pipe section " " ELBOW SET ONLY can then be installed over the flue pipe section with "...
  • Page 8 Venting installatiOn Continued See Detail A Existing 2" Min. Ceiling Frame Firestop Spacer Straps Straps Screws or Detail B Staples Angle Firestop See Detail B (Min. of 8) Figure 10 - Firestop Spacer with Living Space Above Ceiling Screws or Staples Firestop Straps (Min.
  • Page 9 Venting installatiOn Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down Continued until it is snug against the open edge of the Minimum Measurements flashing (see Figure 14). Use SC1 for all round terminations and SC2 for all terminations with "...
  • Page 10 Venting installatiOn Continued 10 FOOT RULE Terminations with 16" slip pipe sections are available. The RTT-8DM and RTTL-8DM are All flue gas outlet chimney terminations must approved for flashing installations. When extend a minimum of 3 feet in height above the needed, these adjustable terminations may be highest point where it passes through the roof used in combination with the pipe assembly to...
  • Page 11: Optional Gas Line Installation

    Venting installatiOn Continued EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP MIN. HEIGHT OF 22 FT. (WITH 2 ELBOW SETS) MAX. HEIGHT OF 50 FT. MAX. HEIGHT 50 FT. (ANY SYSTEM) EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP 14.5 FT.
  • Page 12: Operation And Maintenance Guidelines

    FIED SERVICE PERSON. ing a fire, do not use the fireplace to cook or warm food. Note: A FMI PRODUCTS, LLC hood must be installed when using an unvented gas log set (see Accessories on page 16). WARNING: If the fireplace...
  • Page 13 Always keep the WARNING: Risk of fire! Re- fire well back from the doors and never allow place grate with FMI PRODUCTS, flames to contact the glass. LLC model 111028-01 only. This grate has been designed to keep...
  • Page 14: Parts

    paRts WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, VS36(1), VS36H(1), VS36R AND VS36RH 37/38 www.fmiproducts.com 111026-01G...
  • Page 15 paRts WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, VS36(1), VS36H(1), VS36R AND VS36RH This list contains replaceable parts used in your fireplace. NO. PART NO. DESCRIPTION QTY. 106638-01 Insulation Pan Fireplace Top 106641-01 Fireplace Surround 106642-01 Air Rod Retainer 106643-01 Damper Rod Retainer Firebox Bottom Firebox Surround...
  • Page 16 paRts WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, VS36(1), VS36H(1), VS36R AND VS36RH Right Side Rear Bottom Front Bottom Left Side REFRACTORY BRICK NO. PART NO. DESCRIPTION QTY. 106658-03 Left Refractory, Textured White Brick • 108164-03 Left Refractory, Textured White Herringbone •...
  • Page 17: Technical Service

    You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.
  • Page 18 accessORies Continued ROUND TOP TERMINATIONS RT-8DM, RTL-8DM ROUND TOP TERMINATIONS OUTSIDE AIR KIT FOR SIDE WALL WITH SLIP SECTION INSTALLATION - AK4 RTT-8DM, RTTL-8DM ROUND TOP TERMINATIONS WITH LOUVERS RTL-8DM OUTSIDE AIR KIT FOR FLOOR INSTALLATION - AK4F STORM COLLAR SC1-1 For RT-8DM and RTL-8DM SC2-1 For RTT-8DM and RTTL-8DM SQUARE CHASE-TOP...
  • Page 19 nOtes _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ www.fmiproducts.com 111026-01G...
  • Page 20: G Www.fmiproducts.com

    2701 S. Harbor Blvd. Santa Ana, CA 92704 111026-01 1-866-328-4537 Rev. G www.fmiproducts.com 09/09...