FMI V)S42 SERIES Owners Manual And Installation Manual

FMI V)S42 SERIES Owners Manual And Installation Manual

Residential and outdoor burning fireplace

Advertisement

RESIDENTIAL AND OUTDOOR WOOD BURNING FIREPLACE
OWNER'S OPERATION AND INSTALLATION MANUAL
PFS
®
C
US
ICC-ES #ESR-2542
MODELS (V)S42 SERIES
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
This fireplace is approved for use as a wood burning
fireplace or for use with a vented gas log approved to
ANS Z21.60, Z21.84 standards or for use with a vent-free
gas log heater approved to ANS Z21.11.2 standard. A FMI
PRODUCTS, LLC hood must be installed when using a
vent-free log heater (see , page 16).
This wood burning fireplace complies with UL127-
CAN/ULC-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, fire department,
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V)S42 SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMI V)S42 SERIES

  • Page 1 ANS Z21.60, Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A FMI PRODUCTS, LLC hood must be installed when using a vent-free log heater (see , page 16).
  • Page 2: Table Of Contents

    • Do not place clothing or other according to this installation manual. Unless you use FMI PRODUCTS, LLC flammable materials on or near components, which have been designed the appliance. and tested for the fireplace system, you •...
  • Page 3: Specifications

    SPECIFICATIONS ELECTRICAL 1" AIRSPACE OUTLET TO COMBUSTIBLE RIGHT SIDE GAS LINE 0" TO MATERIAL KNOCK OUTS TOP SPACERS NO COMBUSTIBLE MATERIAL ON FACE 8.125" 2.5" 6.75" 10.625" 12" AIR KIT KNOCK OUT LEFT SIDE GAS LINE COMBUSTIBLE KNOCK OUTS WALL BOARD 3/4"...
  • Page 4: Fireplace Installation

    FIREPLACE INSTALLATION SELECTING LOCATION FRAMING To determine the safest and most efficient 1. Frame opening for the fireplace using location for the fireplace, you must take into dimensions shown in Figures 1 and 2. consideration the following guidelines: 2. If fireplace is to be installed directly on 1. The location must allow for proper clear- carpeting, tile (other than ceramic) or any ances (see Figures 1 and 2).
  • Page 5: Hearth Extension

    FIREPLACE INSTALLATION DRAIN PAN (DP42) WARNING: Hearth extension For outdoor installations, the fireplace enclo- is to be installed only as shown sure must allow for adequate drainage and in Figure 3. fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with MANTELS provision for drainage be installed under the fireplace within the fireplace enclosure (see A mantel may be installed if desired (see Accessories, page 16).
  • Page 6: Venting Installation

    Hemmed Figure 5 - Outside Air Kit 8" Stainless Inner Pipe CHIMNEY PIPE The FMI PRODUCTS, LLC chimney system consists of 12", 18", 24", 36" and 48" snap- Figure 6 - Lineal Gain lock, double-wall pipe segments, planned for maximum adaptability to individual site ASSEMBLY AND INSTALLATION OF requirements. Actual lengths gained after fit-...
  • Page 7 VENTING INSTALLATION Continued Continue to assemble chimney sections as OFFSET RISE CHIMNEY LENGTH outlined, making sure that both the inner and 48" 36" 24" 18" 12" outer pipe sections are locked together. When " " ELBOW SET ONLY installing double wall snap-lock chimney " " together, it is important to assure the joint be- "...
  • Page 8 VENTING INSTALLATION Continued See Detail A Existing 2" Min. Ceiling Frame Firestop Spacer Straps Straps Screws or Detail B Staples Angle Firestop See Detail B (Min. of 8) Figure 10 - Firestop Spacer with Living Space Above Ceiling Screws or Staples Firestop Straps (Min. of 8) Straps Spacer Existing Detail A Ceiling Return Elbow Frame Figure 8 - Ceiling Support Pipe 12S-8DM Figure 11 - Firestop Spacer with Attic Space Above Ceiling...
  • Page 9 VENTING INSTALLATION Continued Minimum Measurements Storm Collar Installation (SC1 or SC2) " Place storm collar over pipe and slide down (36.5 cm) 30" 1" until it is snug against the open edge of the (76.2 cm) (2.5 flashing (see Figure 14). Use SC1 for all round 1" terminations and SC2 for all terminations (2.5 cm) with slip sections.
  • Page 10: Chase Installations

    VENTING INSTALLATION Continued 10 FOOT RULE Terminations with 16" slip pipe sections are available. The RTT-8DM and RTTL-8DM are All flue gas outlet chimney terminations must approved for flashing installations. When extend a minimum of 3 feet in height above the needed, these adjustable terminations may be highest point where it passes through the roof used in combination with the pipe assembly to and must be at least 2 feet above the high- achieve the correct chimney height.
  • Page 11: Optional Gas Line Installation

    VENTING INSTALLATION Continued EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP MIN. HEIGHT OF 22 FT. (WITH 2 ELBOW SETS) MAX. HEIGHT OF 50 FT. MAX. HEIGHT 50 FT. (ANY SYSTEM) EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP 14.5 FT.
  • Page 12 FIED SERVICE PERSON. ing a fire, do not use the fireplace to cook or warm food. Note: A FMI PRODUCTS, LLC hood must be installed when using an unvented gas log set (see Accessories on page 16). WARNING: If the fireplace...
  • Page 13: Operation And Maintenance Guidelines

    OPERATION AND MAINTENANCE GUIDELINES GLASS DOORS Glass doors are optional with the fireplace. When the fireplace is in operation, doors must be fully opened or fully closed position Doors Fully Closed only or a fire hazard may be created (see Fireplace Front Figure 21). A fireplace equipped with glass doors oper- ates mush differently than a fireplace with an open front. A fireplace with glass doors has a...
  • Page 14 Outside Air Handle Retainer Kit Handle WARNING: Risk of fire! Re- Figure 22 - Damper and Air Kit Handle place grate with FMI PRODUCTS, LLC model 111100-01 only. This grate has been designed to keep the operation of your fireplace safe and efficient.
  • Page 15: Parts

    PARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH Right Side Rear Bottom Front Bottom Left Side REFRACTORY BRICK NO. PART NO. DESCRIPTION QTY. 107812-03 Left Refractory, Textured White Brick • 108169-03 Left Refractory, Textured White Herringbone • 107812-02 Left Refractory, Textured Red Brick • • 108169-02 Left Refractory, Textured Red Herringbone •...
  • Page 16 PARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH 37/38 www.fmiproducts.com 111099-01L...
  • Page 17 PARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH This list contains replaceable parts used in your fireplace. NO. PART NO. DESCRIPTION QTY. 107797-01 Insulation Pan Fireplace Top 107800-01 Fireplace Surround 106642-01 Air Rod Retainer 106643-01 Damper Rod Retainer Firebox Bottom Firebox Surround Air Separator See Page 15 Left Refractory See Page 15 Right Refractory See Page 15 Rear Refractory See Page 15 Bottom Rear Refractory See Page 15 Bottom Front Refractory 106683-01 Firebox Support Leg...
  • Page 18: Accessories

    ACCESSORIES DOUBLE WALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT BI-FOLD GLASS DOOR BDO42 - Black BDO42B - Brushed Brass BDO42P - Platinum ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM 30°...
  • Page 19 ACCESSORIES Continued OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION - AK4 MESH ROUND TOP TERMINATIONS RT-8DM MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT-8DM OUTSIDE AIR KIT FOR FLOOR INSTALLATION - AK4F ROUND TOP TERMINATIONS WITH LOUVERS RTL-8DM ROUND TOP TERMINATIONS WITH SQUARE CHASE-TOP LOUVERS WITH SLIP SECTION TERMINATION...
  • Page 20 2701 S. Harbor Blvd. Santa Ana, CA 92704 111099-01 1-866-328-4537 Rev. L www.fmiproducts.com 03/11 www.fmiproducts.com 111099-01L...