OWNER'S OPERATION AND INSTALLATION MANUAL
PFS
C
NATURAL GAS "TUDOR" MODELS (V)T32N-A, AND (V)TC32N
SERIES, CGDV32NR AND CTDV32NR-HA
PROPANE/LP GAS "TUDOR" MODELS (V)T32P-A, AND (V)TC32P
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
DIRECT-VENT FIREPLACE
®
US
SERIES AND CGDV32PR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tudor T32N-A series, Tudor TC32N series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMI Tudor T32N-A series, Tudor TC32N series

  • Page 1 DIRECT-VENT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL ® NATURAL GAS “TUDOR” MODELS (V)T32N-A, AND (V)TC32N SERIES, CGDV32NR AND CTDV32NR-HA PROPANE/LP GAS “TUDOR” MODELS (V)T32P-A, AND (V)TC32P SERIES AND CGDV32PR WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..............2 Cleaning and Maintenance ........ 30 Product Identif cation ........... 4 Replacement Parts ..........32 Local Codes............4 Service Hints ............. 32 Product Features ..........4 Technical Service..........32 Pre-Installation Preparation ......... 5 Specif cations ............ 32 Location of Termination Cap ........
  • Page 3 SAFETY Continued Carbon Monoxide Poisoning: Early signs of Keep the appliance area clear carbon monoxide poisoning resemble the f u, and free from combustible ma- with headaches, dizziness or nausea. If you have these signs, the f replace may not be terials, gasoline and other flam- working properly.
  • Page 4: Product Identif Cation

    SAFETY Continued a qualif ed service person. If needed, have ANSI/NFPA 70. venting system cleaned or repaired. See 11. Do not use f replace if any part has been Cleaning and Maintenance, page 30. under water. Immediately call a qualif ed 9.
  • Page 5: Pre-Installation Preparation

    Determine the safest and most eff cient location sive snow or ice build up may occur . Be sure for your FMI PRODUCTS, LLC direct-vent f re- to clear vent termination area after snow falls place. Make sure that rafters and wall studs are to prevent accidental blockage of venting not in the way of the venting system.
  • Page 6 PRE-INSTALLATION PREPARATION Continued NOTICE: This fireplace is in- tended for use as supplemental " " " heat. Use this fireplace along " with your primary heating sys- tem. Do not install this fireplace as your primary heat source. " If you have a central heating "...
  • Page 7: Location Of Termination Cap

    LOCATION OF TERMINATION CAP Fixed Openable Fixed Closed Closed Openable TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or I = clearance to service regulator vent outlet [*72" (182.9 cm) minimum] balcony [*12"...
  • Page 8 REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS For all side wall horizontally vented gas fueled INSPECTION equipment installed in every dwelling, building or The state or local gas inspector of the side structure used in whole or in part for residential wall horizontally vented gas fueled equipment purposes, including those owned or operated by shall not approve the installation unless, upon...
  • Page 9: Venting Installation

    Failure to do so could result in These models are tested and approved for use with FMI PRODUCTS, LLC (direct-vent) serious injury, property damage pipe components and terminations. or loss of life. The venting system must terminate on the...
  • Page 10: Venting Installation

    VENTING INSTALLATION Continued 5. Carefully determine location where vent INSTALLATION PLANNING pipe assembly will penetrate the outside There are two basic types of direct-vent wall. The center of hole should line up with installation: center line of horizontal vent pipe. Mark •...
  • Page 11 VENTING INSTALLATION Continued 6. Noncombustible Exterior Wall: Position Slide wall f restop against interior wall horizontal vent cap in center of the 8 " surface and attach with screws provided round hole and attach to exterior wall with (see Figure 12). See Figure 13, page 12, four screws (see Figure 10).
  • Page 12 VENTING INSTALLATION Continued GROUND FLOOR INSTALLATION Siding Recommended Applications: Standoff • Installation using cabinet surrounds Minimum Pipe • Through the wall using round or square Screws Overlap 1 " termination (up to 12") adjustable pipe) • NOT FOR CORNER INSTALLATION Wall 45°...
  • Page 13 VENTING INSTALLATION Continued CORNER INSTALLATION Recommended Applications: • Corner ground f oor installation • Ground f oor installation where pipe vents horizontally through wall (over 12" horizontal pipe) • Basement installation where one foot clearance from ground to termination is possible Not to Exceed 90°...
  • Page 14 VENTING INSTALLATION Continued HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following con f gurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. Venting with Two 90° Elbows Horizontal (H Vertical (V) Horizontal (H Horizontal (H 5' min.
  • Page 15 VENTING INSTALLATION Continued INSTALLATION FOR VERTICAL Flat Ceiling Installation 1. Cut a 11 " square hole in ceiling using TERMINATION locating hole as a center point. Opening Note: Vertical restrictor must be installed in should be framed to 1 1 "...
  • Page 16 VENTING INSTALLATION Venting with One 90° Elbow Vertical (V) Horizontal (H) Continued 5' min. 2' max. vent pipe to combustible materials. 6' min. 4' max. 6. Continue to add pipe sections until height 7' min. 6' max. of vent cap meets the minimum building 8' min.
  • Page 17 Note: Install restrictor into inner PARTS LIST FOR VENTING KITS collar of fireplace as shown. AND COMPONENTS FMI PRODUCTS, LLC (5"/8") Pipe & Vent Kits Number Description P58-6 6" Section Double Wall Pipe, Galvanized P58-12 12" Section Double Wall Pipe, 45°...
  • Page 18: Fireplace Installation

    VENTING INSTALLATION Continued Number Description Number Description VKC-58 Corner Vent Kit, Galvanized ST-58-14 14" Snorkel Termination, Galva- (Includes 45° Elbow, 7"-12" nized Adjustable Pipe, Wall Firestop, ST-58-36 36" Snorkel Termination, Galvanized Horizontal Termination, 6" Pipe, SC-58 Storm Collar, Galvanized 90° Elbow, 18 Screws) WF-58 Wall Firestop, Galvanized HHTK-58 High Wind Round Horizontal Termi-...
  • Page 19 FIREPLACE INSTALLATION Continued 4. Be certain that all wire terminals are 9. Check to make sure that power cord is securely attached to terminals on blower completely clear of blower wheel and motor and that screw retaining green that there are no other foreign objects in ground wire is tight.
  • Page 20 FIREPLACE INSTALLATION Continued 3. Place blower against lower rear wall of 7. Check to make sure that power cord is f rebox outer wrapper with exhaust port di- completely clear of blower wheel and rected upward and thermodisc positioned that there are no other foreign objects in up near fireplace bottom.
  • Page 21 FIREPLACE INSTALLATION Continued f replace regulator damage could occur . Install INSTALLING GAS PIPING TO external regulator with the vent pointing down FIREPLACE LOCATION as shown in Figure 31. Pointing the vent down protects it from freezing rain or sleet. WARNING: A qualified service person must connect CAUTION: Use only new,...
  • Page 22 FIREPLACE INSTALLATION Continued We recommend that you install a sediment To Gas Supply trap/drip leg in supply line as shown in Figure (Natural) Equipment 32. Locate sediment trap/drip leg where it is Shutoff within reach for cleaning. Install in piping sys- Valve Control Valve tem between fuel supply and f replace.
  • Page 23 FIREPLACE INSTALLATION Continued Test Pressures Equal To or Less Than PRESSURE TESTING FIREPLACE GAS 1/2 PSIG (3.5 kPa) CONNECTIONS 1. Close equipment shutoff valve (see Fig- 1. Open equipment shutoff valve (see Fig- ure 34). ure 34). 2. Pressurize supply piping system by either 2.
  • Page 24 FIREPLACE INSTALLATION Continued INSTALLING OPTIONAL WIRELESS Removing Louver Panels Remove top and bottom louver panels by HAND-HELD REMOTE CONTROL simultaneously pulling both top end spring TRC AND MRC SERIES latches towards center of appliance until they are disengaged from locating holes NOTICE: Use only alkaline bat- (see Figure 39).
  • Page 25 FIREPLACE INSTALLATION Continued Press in on the bottom of door screen until INSTALLING OPTIONAL BRICK magnetic door latch is pushed in. LINER MODEL BL32D Removing Glass Door If replacement of glass is necessary , the WARNING: If fireplace has entire assembly, glass and frame, must be been running, turn off and un- replaced.
  • Page 26 FIREPLACE INSTALLATION Continued 7. Install right brick panel using the same 5. Place log #5 (base log) onto front left part of method described in step 5 for left brick grate making sure notches f t over prongs panel. of grate). See Figure 48, page 27. 8.
  • Page 27: Operation

    FIREPLACE INSTALLATION Continued 6. Place log #6 (left log) onto two pins on left material to cover pilot ports. It is not nec- essary to use all of the ember material side of back and front log. See Figure 48. provided.
  • Page 28 OPERATION Continued LIGHTING TO TURN OFF GAS INSTRUCTIONS TO APPLIANCE 1. STOP! Read the safety information on 1. Open lower louver panel. page 27. 2. Set selector switch in the OFF position to 2. Open lower louver panel. prevent draining battery. 3.
  • Page 29: Inspecting Burners

    OPERATION Continued Blower Control Knob blower with optional thermostat (wall mounted Variable (Optional Accessory) or remote control) for the f replace, your f re- Control Knob place and blower will not turn on and of f at the same time. Fireplace may run for several minutes before blower turns on.
  • Page 30: Cleaning And Maintenance

    INSPECTING BURNERS Continued If the vent conf guration is installed incorrectly , f ames will lift or "ghost". This can be danger- WARNING: Do not use ous. Inspect f ames after installation to ensure abrasive cleaners as this may proper installation and performance. damage glass.
  • Page 31 CLEANING AND MAINTENANCE Continued Use only the tempered glass door replace- VENTING SYSTEM ment intended for this f replace (see Replace- Conduct annual inspection of venting system ment Parts, page 32 for detail on ordering). No following these guidelines: substitutions may be made. See Removing/ 1.
  • Page 32: Replacement Parts

    • propane/LP gas supply might be low (pro- heater ready. pane/LP units only) You can also visit FMI PRODUCTS, LLC’ s You may feel your gas pressure is too low. If web site at www.fmiproducts.com. so, contact your local gas supplier.
  • Page 33: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 34: Troubleshooting

    TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot lights but f ame goes 1. Gas control knob not fully 1. Press in gas control knob out when control knob is pressed in fully released 2. G a s c o n t r o l k n o b n o t 2.
  • Page 35 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. Turning gas control knob Heater produces a whistling 1. Turn gas control knob to LO to HI position when burner noise when burner is lit position and let warm up for is cold a minute 2.
  • Page 36 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 37: Accessories

    Purchase these accessories from your local dealer. If they can not supply these accessories THERMOSTATICALLY- call FMI PRODUCTS, LLC at 1-866-328-4537 CONTROLLED BLOWER KIT - BKT for information. You can also write to the ad- Provides better heat distribution. Blower turns dress listed on the back page of this manual.
  • Page 38: Parts

    PARTS MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V)T32NRB-A, (V)T32P-A, (V) T32PB-A, (V)T32PR-A, (V)T32PRB-A, (V)TC32(N)(P), (V)TC32(NB)(PB), (V) TC32N-HA, CGDV32NR, CGDV32PR AND CTDV32NR-HA 22-3 22-5 22-4 22-6 22-2 22-1 parts can be purchased at : www.allpartsinc.com 1-877-475-5660...
  • Page 39 PARTS This list contains replaceable parts used in your f replace. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual. PART NUMBER CGDV32NR CGDV32PR CTDV32NR-HA (V)T32NR-A (V)T32PR-A (V)T32NRB-A (V)T32PRB-A (V)T32N-A (V)T32P-A (V)TC32(N)(P) (V)T32NB-A (V)TC32(NB)(PB) (V)T32PB-A (V)TC32N-HA...
  • Page 40 PARTS BURNER ASSEMBLY MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V) T32NRB-A, (V)T32P-A, (V)T32PB-A, (V)T32PR-A, (V)T32PRB-A, (V)TC32(N)(P), (V)TC32(NB)(PB), TC32N-HA CGDV32NR, CGDV32PR AND CTDV32NR-HA parts can be purchased at: www.allpartsinc.com 1-877-475-5660...
  • Page 41 PARTS BURNER ASSEMBLY MODELS (V)T32N-A, (V)T32NB-A, (V)T32NR-A, (V) T32NRB-A, (V)T32P-A, (V)T32PB-A, (V)T32PR-A, (V)T32PRB-A, (V)TC32(N)(P), (V)TC32(NB)(PB), (V)TC32N-HA, CGDV32NR, CGDV32PR AND CTDV32NR- This list contains replaceable parts used in your f replace. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual. NO.
  • Page 42 NOTES _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ www.fmiproducts.com 116646-01L...
  • Page 43 NOTES _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ www.fmiproducts.com 116646-01L...
  • Page 44: Warranty

    This is FMI PRODUCTS, LLC’ s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and f tness for a particular purpose to four (4) years on new products and 30 days on factory reconditioned products from the date of f rst purchase.