Clearances; Unit Dimensions - Fedders FV95A054 Installating And Operation Manual

Category i natural gas and lp gas high efficiency two stage variable speed warm air furnace
Table of Contents

Advertisement

CLEARANCES

Table 2 provides the certified clearances to combustibles.
IMPORTANT
This furnace requires a minimum of 24-inches of front
clearance for service purposes. For this purpose, service
clearance
takes
precedence
combustibles.
TABLE 2: CLEARANCES TO COMBUSTIBLES
UPFLOW
1"
TOP
1"
PLENUM
TOP/BOTTOM
0.5"
PLENUM SIDES
UNIT FRONT
0" *
0"
UNIT BACK
0"
UNIT SIDES
UNIT BASE
0" ***
UNIT FLUE PIPE
0"
ENCLOSURE
CLOSET
* 24" REQUIRED FOR SERVICE
** SUPPLY AIR END / RETURN AIR END
*** CERTIFIED FOR CLOSET INSTALLATION ON COMBUSTIBLE FLOORING
**** CERTIFIED FOR INSTALLATION ON COMBUSTIBLE FLOORING ONLY WHEN INSTALLED
ON SPECIAL BASE PART #30476
See the appliance rating plate affixed to the
furnace for specific model number, serial
number
and
clearance
information.
DANGER
COMBUSTIBLE MATERIAL MUST NOT BE PLACED ON OR
AGAINST THE FURNACE JACKET.
PLACEMENT OF COMBUSTIBLE MATERIALS ON, AGAINST
OR AROUND THE FURNACE JACKET CAN CAUSE AN
EXPLOSION OR FIRE RESULTING IN PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
DANGER
THE AREA AROUND THE FURNACE MUST BE KEPT CLEAR
AND FREE OF ALL COMBUSTIBLE MATERIALS INCLUDING
GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.
THE HOMEOWNER SHOULD BE CAUTIONED THAT THE
FURNACE AREA MUST NOT BE USED AS A BROOM
CLOSET OR FOR ANY OTHER STORAGE PURPOSE.
UPFLOW FURNACES ARE DESIGN CERTIFIED FOR
INSTALLATION ON COMBUSTIBLE FLOORS. THIS SHALL
BE INTERPRETED AS A WOOD FLOOR ONLY.
THE FURNACE MUST NOT BE INSTALLED DIRECTLY ON
CARPETING, VINYL TILE, OR OTHER COMBUSTIBLE
MATERIAL
EXCEPT
WOOD.
COMBUSTIBLE MATERIAL CAN RESULT IN FIRE, CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
over
clearance
to
HORIZONTAL
COUNTERFLOW
0"
2"
1"
2.5"
0.5"
0.5"
0" *
0" *
0"
0"
0"
1" **
0"
0" ****
0"
0"
CLOSET
CLOSET
ALL DIMENSIONS IN INCHES
to
combustibles
INSTALLATION
ON
FIGURE 2: DIMENSIONS
1
G
A
TABLE 3: DIMENSIONS
DIMENSIONS (Inches)
WIDTH
A
54,000
17.5
72,000
20.5
90,000
20.5
108,000
24.5
MODEL
SIDE
INPUT
D x E
14 x 22
54,000
14 x 22
72,000
90,000
14 x 22
14 x 22
108,000
1
Vent outlet 4" - Use reducer fittings.
2
Two return air openings required
6
K
F
B
G
C
E
DEPTH
HEIGHT
B
C
29
40
29
40
29
40
29
40
RETURN
BOTTOM
J x K
L
16 x 19
3/4
19 x 19
3/4
19 x 19
3/4
23 x 19
3/4
L
J
L
D
SUPPLY
F x G
16.5 x 19
19.5 x 19
19.5 x 19
24 x 19
VENT
H
2
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fv95a072Fv95a090Fv95a108