Timeout Between Decodes

Timeout Between Decodes, Same Symbol
This parameter sets the minimum time between decodes of different symbols. It is programmable in 0.1-second increments from 0.0
to 9.9 seconds. Setting this above 0.4 seconds is recommended.) The default for this parameter is 0.6 seconds.
Scan the bar code below to select a new timeout. Next, scan two numeric bar codes beginning in
that correspond to the desired timeout. Single digit numbers must have a leading zero. For example, to set a timeout of 0.5 seconds,
scan the bar code below, then scan the "0" and "5" bar codes. If an error is made, or to change a selection, scan
Timeout Between Decodes, Different Symbol
This parameter sets the minimum time between decodes of different symbols. It is programmable in 0.1-second increments from 0.0
to 9.9 seconds. The default for this parameter is 0.2 seconds.
Scan the bar code below to select a new timeout. Next, scan two numeric bar codes beginning in
that correspond to the desired timeout. Single digit numbers must have a leading zero. For example, to set a timeout of 0.5 seconds,
scan the bar code below, then scan the "0" and "5" bar codes. If an error is made, or to change a selection, scan
Timeout Between Same Symbol
Timeout Between Different Symbol
Numeric Bar Codes on page D-1
Cancel on page
Numeric Bar Codes on page D-1
Cancel on page
D-8.
D-8.