Installation Place; Electrical Work; When Using The Air Conditioner Again; Specifications - Mitsubishi Electric MR. SLIM MCF-D18VD Operating Instructions Manual

Split-type air conditioners indoor unit
Table of Contents

Advertisement

Available languages

Available languages

W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
This dries the inside of the unit.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.

When using the air conditioner again:

1
Clean the air fi lter.
Page 6
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
S
PECIFICATIONS
Model
Indoor
Dimensions
H × W × D (mm)
Outdoor
Indoor
Weight (kg)
Outdoor
Note:
1. Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB, 24°C WB
2. Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
21°C DB
Lower limit
15°C WB
Environment care
Mitsubishi Electric Air conditioner has been designed environment-friendly. The plastic composition can be used as recycle part.
For the optimum effi ciency and energy saving, users are recommended to operate air conditioners as following suggestion.
Turn off air conditioner in case of not in use.
Turn off ventilator in case of not in use.
The set temperature should not be set lower than 25°C.
The cleaning of condensing coil should be performed at least every 3 months.
The cleaning of air cleaning fi lter should be performed in the period described in this manual.
Page 4
MCF-SD13VD
650 × 1100 × 180
550 × 800 × 285
26
34
Outdoor
43°C DB
21°C DB
I
NSTALLATION PLACE AND

ELECTRICAL WORK

Installation place

Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
Inverter-type
fl uorescent lamp
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
Keep a space to
prevent the pic-
ture distortion or
the noise.
1 m
or more
TV
1 m
or more
Cordless
phone or
Portable
phone
Radio
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
MCF-D18VD
650 × 1100 × 180
850 × 840 × 330
26
54
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
wall, etc.
Well-
ventilated dry
place
100 mm or
more
200/500 mm
or more
3 m or
more
SD13/D18, D24
MCF-D24VD
650 × 1100 × 180
850 × 840 × 330
26
65
En-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr. slim mcf-d24vdMr. slim mcf-sd13vd

Table of Contents